CDVI KCIN Installation Manual page 5

Illuminated weatherproof keypad with remote electronics
Hide thumbs Also See for KCIN:
Table of Contents

Advertisement

Available languages

Available languages

INSTALLATION MANUAL
KCIN
Illuminated weatherproof Keypad with Remote Electronics - 2 or 3 relays
and faster to change its code.
1. Enter the master code twice
(1 2 3 4 5 default value master code).
2 beeps are emitted to confirm entry
in programming mode.
2. Press A7 to program a sub master
code for the user individual Pin
code modification.
One beep is emitted. Enter the new
2-digit sub master code. One beep
is emitted to confirm programming
of the sub master code.
3. Press B to exit from
the programming mode.
2 beeps are emitted to confirm
that the keypad is in stand-by
operating mode.
I. Audible Feedback
The audible signal is enabled
in programming mode
and when the relay is energised
after a valid code.
To enable the audible feedback
on a key press:
1. Enter the master code twice
(1 2 3 4 5 default value master code).
2 beeps are emitted to confirm entry
in programming mode.
2. Press AA.
One beep is emitted. Press 0 to disable
the audible signal during a keypress.
Press 1 to enable the audible signal
during a keypress. One beep confirms
the new setting.
3. Press B to exit from programming.
2 beeps are emitted to confirm exit
from programming mode.
8
8
cdvigroup.com
EN
J. OPTIONAL KCIN 2 AND KCIN 3
PROGRAMMING INSTRUCTION
Programming instructions are the same
as for the KCIN keypad with 1
relay output.
KCIN 2: 2 relay outputs N/O
and N/C contacts 8A @ 250V~.
Group 1: From user location 00
to user location 59 to activate relay 1.
Group 2: from user location 60
to user location 99 to activate relay 2
Release Time of relay2 enter A2,
sub master code enter A8
(default values 1 and 3).
KCIN 3: 3 relay outputs N/O
and N/C contacts 8A @ 250V~.
Group 1: from user location 00
to user location 59 to activate relay 1.
Group 2: from user location 60
to user location 79 to activate relay 2.
Group 3: from user location 80
to user location 99 to activate relay 3.
Release time for relay 3 enter A3
sub master code enter A9
(default values 4 and 6).
INSTALLATION MANUAL
KCIN
Illuminated weatherproof Keypad with Remote Electronics - 2 or 3 relays
To program Pin codes:
User
User
Code
Name
location
location
00
34
01
35
02
36
03
37
04
38
05
39
06
40
07
41
08
42
09
43
10
44
11
45
12
46
13
47
14
48
15
49
16
50
17
51
18
52
19
53
20
54
21
55
22
56
23
57
24
58
25
59
26
60
27
61
28
62
29
63
30
64
31
65
32
66
33
67
KCIN 1 Relays (1 output)
Relay 1 : From user location
REMINDER
00 to 99.
User
Code
Name
Code
location
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
KCIN 2 Relays (2 output)
KCIN 3 Relays (3 outputs)
Relay 1 : From 00 to 59,
Relay 1 : From 00 to 59,
Relay 2 : From 60 to 99.
Relay 2 : From 60 to 79,
Relay 3 : From 80 to 99.
cdvigroup.com
EN
Name
9
9

Advertisement

Table of Contents
loading