Setup (Initial Settings)
5
Set the LOCAL/MENU/REMOTE switch to the
LOCAL or REMOTE position.
The unit is set to the menu protect mode.
When the LOCAL/MENU/REMOTE switch is set
to the MENU position, the menu setting mode is
not established, and "MENU PROTECTED"
appears on the video monitor screen.
<Note>
If the LOCAL/MENU/REMOTE switch is set to
the MENU position while holding down the
COUNTER button on the front panel, the menu
setting mode will be established and the regular
menu settings can be performed even in the
menu protect mode.
2
Perform steps
through
using on-screen menus." (See page 23)
How to release the menu
protection
1
Set the LOCAL/MENU/REMOTE switch to the
MENU position while holding down the
COUNTER button on the front panel.
The unit is set to the menu setting mode, and the
menu screen appears on the video monitor.
2
2
Perform steps
and
menus." and a screen for checking whether to
protect the menus appears on the video
monitor.
MENU PROTECT OK?
NO
YES
3
Press the MENU-UP button or MENU-DOWN
button to move the cursor to the NO position,
and press the SET button.
The menu protection is now released.
7
of "Setting method
3
of "How to protect the

How to display the DIAG menu

This unit has a function for displaying hour meters,
software version and the deck's serial number on the
video monitor.
1
Set the LOCAL/MENU/REMOTE switch to the
MENU position while holding down the EJECT
button.
The unit is set to the diagnosis display mode, and
"HOURS METER" appears on the video monitor.
DIAG–MENU
Ser
H00 OPERATION
H01 DRUM RUN
H02 TAPE RUN
H03 THREADING
H11 DRUM RUN r
H12 TAPE RUN r
H13 THREADING r
Any item with "r" can be reset when servicing is
performed.
2
While the hour meters are displayed, press
the MENU-UP button or MENU-DOWN button
while holding down the PAGE button.
The deck's serial number and software version
are displayed on the video monitor.
DIAG–MENU
<NTSC>
FRONT
IF
AV-SYSCON
DV
CYLINDER
REEL
When the MENU-UP button or MENU-DOWN
button is pressed again while holding down the
PAGE button, operation returns to the hour meter
display.
3
Set the LOCAL/MENU/REMOTE switch to the
LOCAL or REMOTE position.
Operation now returns to the normal mode.
26
HOURS METER
00000H
00000H
00000H
00000T
00000H
00000H
00000T
VERSION
1.
-
1.
-
- .
1.
-
- .
1.
-
- .
1.
-
- .
1.
-
- .

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Aj-d95Aj-d95dcAj-d95dcpDvcpro 50 aj-d95dcp