Connectors And Electrical Data - Siemens SCALANCE X308-2M Operating Instructions Manual

Industrial ethernet switches
Hide thumbs Also See for SCALANCE X308-2M:
Table of Contents

Advertisement

Technical specifications
8.6 XR-300M EEC technical specifications
8.6.2

Connectors and electrical data

Table 8- 69
Max. number
Electrical
Media module slots
Transmitter output (optical) and receiver input
Diagnostics port
Table 8- 70
Device version
(power supply)
1 x 24 to 48 VDC
2 x 24 to 48 VDC
1 x 100 to 240 VAC /
60 to 250 VDC
2 x 100 to 240 VAC /
60 to 250 VDC
Table 8- 71
Device version
(power supply)
24 to 48 VDC
100 to 240 VAC /
60 to 250 VDC
186
Connection for end devices or network components
Electrical data: Power supply
Redundant
power supply
unit
Electrical data: Current consumption and power loss
24 ports
16 x RJ-45 jacks
10/100/1000 Mbps
4 x modular
(2 ports per slot)
The values correspond to those of the permitted
MM900 media modules and SFP transceivers.
RJ-11 jack
Redundant power
supply possible
No
Yes
Yes
Yes
No
No
Yes
No
Current consumption
1.6 to 0.75 A
0.6 to 0.37 A (AC)
0.7 to 0.17 A (DC)
Operating Instructions, 02/2012, A5E01113043-12
Power supply
(min./max. range)
24 to 48 VDC
(19.2 to 57.6 VDC)
24 to 48 VDC
(19.2 to 57.6 VDC)
100 to 240 VAC
(80 to 276 VAC)
60 to 250 VDC
(48 to 300 VDC)
100 to 240 VAC
(80 to 276 VAC)
60 to 250 VDC
(48 to 300 VDC)
Effective power loss
40 W
42 W (AC)
42 W (DC)
SCALANCE X-300