Siemens SCALANCE X308-2M Operating Instructions Manual page 132

Industrial ethernet switches
Hide thumbs Also See for SCALANCE X308-2M:
Table of Contents

Advertisement

Connecting
6.4 Power supply
Connecting a redundant power supply to 1 power supply unit
Use the left terminal block to connect the power supply. The terminal block is marked "X1":
L1 M1
Figure 6-1
Assignment of the LED display to the pins for redundant power supply with devices with one
power supply unit
● If the power supply fails at pins L1/M1, this is indicated by LED L1.
● If the power supply fails at pins L2/M2, this is indicated by LED L2.
Connecting a redundant power supply to 2 power supply units
To connect the power supplies, use pins L1/M1 of the left terminal block and pins L1/M1 of
the right terminal block. The left terminal block is marked "X1" and the right terminal block
"X2".
L1 M1
Figure 6-2
● If the power supply fails at pins L1/M1 of terminal block "X1", this is indicated by LED L1.
● If the power supply fails at pins L1/M1 of terminal block "X2", this is indicated by LED L2.
132
L1 L2
M2
L2
F1
Anschluss_1_Netzteil_X-300EEC
L1 L2
M2
L2
F1
Assignment of the LED display to the pins for redundant power supply with devices with
two power supply units
F2
L1 M1
M2
F2
L1 M1
M2
L2
F1
F2
L2
F1
F2
Operating Instructions, 02/2012, A5E01113043-12
SCALANCE X-300