26

Vertical Pole Mount

Use the following procedures for vertical pole mount installations. Use of the extension arm is recommended
when mounting the access point to poles greater than 3 inches is diameter.
For poles up to 3 inches in diameter when using a U-bolt:
Thread the two inner nuts onto the U-bolt. Place the U-bolt at the desired mounting location.
1.
Place the pole mount bracket section on the U bolt. Adjust the inner nuts until the pole mount bracket section is
2.
against the pole and the U-bolt can be secured tightly to the pole.
Place the angle adapter bracket section on the U-bolt with the open slot connections on the bottom and align it
3.
with the pole mount section.
Put the two outer nuts on the U-bolt to attach the angle adapter bracket section to the pole mount bracket
4.
section.
Tighten all nuts to 300 inch pounds (lbf-in).
5.
Position the access point bracket section so that the bottom of the section with the straight (not bevel cut) side
6.
is oriented toward the bottom side of the AP with the gore vent. Using a torque wrench or a ratchet and a
10mm socket, or an adjustable wrench, attach (but don't tighten) the access point bracket section to the AP
7161 with the with four M6 hex flange screws.
Insert two M6 hex flange screws into the bottom holes on the sides of the access point bracket section.
7.
With the access point positioned so that the gore vent is facing down, insert the two M6 hex flange screws in
8.
the bottom holes on the sides of the access point bracket section into the open slot connections on the bottom
of the angle adapter bracket section.
Rotate the access point bracket section upward and align the top holes on the sides with the top holes on the
9.
angle adapter bracket section. Insert two M6 hex flange screws into the top holes on the angle adapter bracket
section.
Use a torque wrench or a ratchet and a 10mm socket, or an adjustable wrench, to finish attaching the access
10.
point bracket section to the angle adapter bracket section with the M6 hex flange screws in the open slot