Table 1 Events requiring FRU replacements scenarios (continued)
Event ID
FRU
218
Controller
233
HDD
235
Controller
239
CompactFlash
240
CompactFlash
242
CompactFlash
246
Controller
247
Various
307
Controller
313
Controller
314
Various
318
Controller
319
HDD
442
Controller
455
SFP
6
Troubleshooting HPE MSA 1040/2040 Storage
Symptom
The supercapacitor pack is
nearing end-of-life.
The indicated disk type is invalid
and is not enabled in the current
configuration.
An enclosure management
processor (EMP) detected a
serious error.
A timeout occurs while flushing
the CompactFlash.
The CompactFlash hardware
detected an error.
The controller module's
CompactFlash card has failed.
The coin battery is not present
or is not properly seated or has
reached end-of-life.
The FRU ID SEEPROM for the
indicated FRU cannot be read.
FRU ID data might not be
programmed.
A temperature sensor on a
controller FRU detected an
over-temperature condition that
caused the controller to
shutdown.
The indicated controller module
has failed. This event can be
ignored for a single-controller
configuration.
The indicated FRU has failed or
is not operating correctly. This
event follows some other
FRU-specific event indicating a
problem.
A hardware failure occurred: XOR
error.
The indicated available disk has
failed.
Power-On Self-Test (POST)
diagnostics detected a hardware
error.
The controller detected that the
configured host-port link speed
Action Required
Replace on first occurrence.
Replace on first occurrence.
Replace on first occurrence.
Replace the CompactFlash.
Replace the CompactFlash.
Replace the CompactFlash.
Replace on first occurrence.
Replace the FRU indicated.
Verify the following:
The system has two power supplies and both
are running correctly
The ambient temperature is not too warm. The
enclosure operating range is 5–40°C
(41°F–104°F)
Obstructions to airflow.
A module or blank plate resides in every module
slot in the enclosure
If none of these conditions apply, replace the
controller module that reported the error.
Replace on first occurrence.
To determine whether the FRU must be replaced,
see Verifying component failure in the component's
replacement instructions document.
Replace on first occurrence.
Replace on first occurrence.
Replace on first occurrence.
Replace with an SFP that supports a later speed.