TES E- SD Operator's Manual page 55

120 volt electric thermal energy system
Table of Contents

Advertisement

Step #4 - Reduction of vapor saturation levels (humidity) by
dehumidification or evacuation (Dehumidification)
1. Now that we have evaporated the moisture into the air, we
need to remove it from the structure along with the excess
heat. This is accomplished with the exhaust controller, an air
mover, 14" lay flat duct and a duct ring. Set up the exhaust
system to evacuate to the outside of the structure.
Set the Remote Activation temperature to turn on the exhaust
2.
fan using the Smart E-TES Remote Exhaust Fan Control or
use a separate exhaust control unit set to keep the ambient
room temperature below 105ºF . (See Page 16 of this manual
or the instructions included with separate exhaust controller
unit).
Overheating the structure may cause damage
to structure or contents. Controlling the temperature is
important to prevent damage.
Monitor your progress at least daily – more often if practical.
Walls will dry quickly!
Exhaust Controller
MB230
Smart E-TES Remote
Exhaust Fan Control
AT206
© Copyright Tes Drying Systems, 2014
Air Temperature Sensor
AT202
Moisture Sensor
PGE5060
55
Air mover with ducting
connected to Exhaust
Controller
Surface Temperature
Sensor AT200