REMOTE PROBE SHUTDOWN:
If the measured readings of any of the remote probes exceed the set points, the green HEATING
light will turn off, indicating the unit is no longer heating.
AIR TEMPERATURE SHUTOFF
When the AIR TEMPERATURE measured by the probe
exceeds the set point the green HEATING light will turn off
indicating unit has shutoff the power to the heating elements.
The AIR TEMPERATURE screen will be displayed, flashing the
current temperature and the shutoff temperature set point.
When the temperature cools sufficiently the green HEATING
light will turn back on and the unit will again heat up.
The AIR TEMPERATURE SHUTOFF will not shutoff the
power to the heating elements if the AIR TEMPERATURE
probe is not connected.
SURFACE TEMPERATURE SHUTOFF
When the SURFACE TEMPERATURE measured by the probe
exceeds the set point the green HEATING light will turn off
indicating unit has shutoff the power to the heating elements.
The SURFACE TEMPERATURE screen will be displayed,
flashing the current temperature and the shutoff temperature set
point.
When the temperature cools sufficiently the green HEATING
light will turn back on and the unit will again heat up.
The SURFACE TEMPERATURE SHUTOFF will not shutoff
the power to the heating elements if the SURFACE
TEMPERATURE probe is not connected.
© Copyright Tes Drying Systems, 2014
Current Air
Temperature
Current Surface
Temperature
15
Air
Temperature
Set Point
Surface
Temperature
Set Point