installation

Installing the Boiler

Please check that you are familiar with the installation
requirement before commencing work (pages 7 - 11).
The installation accessories described in the following list are
included in the boiler packaging:
- Hanging bracket
- A paper template (showing the dimensions of the boiler with
5 mm side clearances)
- Connection valves (Compression)
- Screws and washers
- Filling loop
- Installation, Servicing and Operating Instructions
- Flue gasket
Method of positioning the boiler on the wall
The paper template can be used to ensure the correct
positioning of kitchen cabinets etc.
The paper template has to be fixed to the wall and used to locate
the position of the hanging bracket and the centre for the flue
hole.
Drill and plug the wall and secure the hanging bracket using
the screws provided. Remove the boiler from it's packaging and
remove the front casing panel.
Place the boiler on the hanging bracket.
N
: t
ote
he
appliaNce
must
Not
be
fitted
Connecting the Boiler to the System
- Remove the boiler casing as described on page 13;
- Remove the caps and connect the valves to the boiler using
the washers provided;
- 4 x fibre washers for the CH flow and return, cold water inlet
and hot water outlet connections;
Safety Valve Discharge and Condense Outlet
The pressure relief valve tube is made of copper. It should
terminate below the boiler safely outside the premises. Care
should be taken that it does not terminate over an entrance or
window or where a discharge of heated water could endanger
occupants or passers by.
Fill the central heating and DHW system and bleed air from the
system as described in the Commissioning instructions (page
6).
The system should be carefully checked for leaks, as frequent
refilling could cause premature system corrosion or unnecessary
scaling of the heat exchanger. The pipe from the trap should be
connected to a drain as described in the relevant regulations.
Pay special attention not to bend the condensate silicone drain
pipe is such a way as to interrupt the flow. Please only use drain
pipe material compatible with condensate products (refer to BS
6798:000).
The condensate flow can reach  litres/hour because of the
acidity of the condensate products (Ph close to ), take care
before operation.
See page 11 for condensate discharge possibiities.
1
Supplied By www.heating spares.co Tel. 0161 620 6677
.
oN
a
combustible
wall
surface
Note: Connections viewed from behind boiler
A
- remove the  screws A from the transport bar
- dispose of the transport bar and reassemble
the fixing screws.
A