Miele PW 6207D Installations Plan page 9

Advertisement

Steam
Steam pressure
connection
Indirect
Boiling point
Mass flow (max. delivery)
Heater rating
On-site threaded union
Steam valve, filter, non-return valve and steam shut-off valve
must be provided on site.
Steam valve supply lead length
The supply lead for the electric steam valve is included.
The steam valve should be installed close to the steam
connection.
Installation instructions for steam-heated washer-extractors
apply throughout.
Condensate
On-site threaded union
connection
A shut-off device and condensate trap must be provided on
site.
The condensate separator must be installed such that when
the system is not operating, the heater bank is completely
emptied. This means that no condensate may remain in the
heater bank. The use of an inverted bucket condensate trap
is recommended.
Cold water
Min. water pressure/flow pressure
(softened water)
Max. water pressure/flow pressure
Flow rate, max.
Max. throughput (if hot and raw water supply is not available)
2 connection hoses with ¾" threaded union incl. Y-piece (¾" /
1") supplied.
On-site threaded union in accordance with DIN 44991 (flat
sealing)
Connection hose length
Average water requirements for a standard 60°C Cottons
programme calculated using cold, hot and hard water
supplies.
In the absence of a hot water supply, add sufficient water to
reach the required amount.
If connecting to raw water, subtract water requirement from
cold water.
Hot water
Max. water intake temperature
(softened water)
Min. water pressure/flow pressure
Max. water pressure/flow pressure
Max. flow rate
1 inlet hose with ¾" threaded union provided.
On-site threaded union in accordance with DIN 44991 (flat
sealing)
Connection hose length
Average water requirements for a standard 60°C Cottons
programme calculated using cold, hot and hard water
supplies.
If no hot water supply available, connect hot water hose to
cold water supply!
Cold water
Min. water pressure/flow pressure
Raw water
Max. water pressure/flow pressure
Flow rate, max.
2 connection hoses with ¾" threaded union including Y-piece
(¾" / 1") included in optional kit.
On-site threaded union in accordance with DIN 44991 (flat
sealing)
Connection hose length
Average water consumption in standard programme (60°
Cottons) when connected to cold, hot and raw water supplies.
Technisches Datenblatt / Technical datasheet: PW 6207 D
Datum / Date: 24.04.2013
kPa
600 - 1000
°C
152 - 184
kg/h
58
kW
32
Inch
½" female thread
mm
500
Inch
½" female thread
kPa
100
kPa
1000
l/min
26
l/min
42
Inch
1" male thread
mm
1500
l/h
approx. 124
°C
70
kPa
100
kPa
1000
l/min
16
Inch
¾" male thread
mm
1500
l/h
Approx. 108
kPa
100
kPa
1000
l/min
32
Inch
1" male thread
mm
1500
l/h
74
Seite / Page:
9