2. ACCESS TO THE PARAMETER CONFIGURATION MENUS

KEY TO DISPLAY (see figure to side)
a
Date: day, month, year
b
Day of the week
c
Pressure in boiler / heating circuit
d
Clock: hour and minutes
To access the list of configuration menus, proceed as follows (consult the
"Description of Symbols" section):
C
B to select the required menu;
without saving.
The list of configuration menus is:
• Information (section 2.1)
• Set time and date (section 2.2)
• Operator unit (section 2.3)
• Time central heating (1,2 - section 5)
• Time central heating CH3 (section 5)
• Time hot water (section 5.3)
• Time auxiliary
• Holiday heating (1,2,3 - section 4.2)
• Temps / mode (1,2,3 - section 4.1.1)
• Temps / mode hot water
• Instantaneous HW heater (not used for this type of boiler)
• Error (section 7)
• Diagnostics heat generation
2.1

INFORMATION MENU

In case a fault arises, the first data displayed is the fault code.
To display boiler information, select " Information" as indicated in section 2.
Boiler temperature
Outside temp
Outside temp min
Outside temp max
DHW temperature
Manifold temperature
State central heating (1,2,3)
State hot water
State boiler
Solar state
Telephone customer service
2.2

TIME AND DATE MENU

To set the time and date, follow the procedure indicated in section 2 and proceed as follows:
• Access the Set time and date menu
B to edit the hour
B to edit 2 (Day / month) and 3 (Year) performing the same procedure as above.
C to return to the previous menu.
2.3

CHANGE LANGUAGE (Operator unit menu)

To set the language, follow the procedure indicated in section 2 and proceed as follows:
• access the Operator unit menu
B to select a language
C to return to the previous menu.
7110317.02 (3-10/14)
B to confirm or
°C
Boiler flow temperature
°C
Outside temp
°C
Minimum memorised outside temperature value (with external probe connected)
°C
Maximum memorised outside temperature value (with external probe connected)
°C
DHW temperature (value read by the boiler DHW circuit probe)
°C
Instantaneous temperature of manifold sensor (with connection to solar plant)
(On/Off)
Heating circuit operating mode (circuits: 1,2,3)
Charging
DHW circuit operating mode
(On/Off)
Boiler operating mode
-
Indicates if sunlight is sufficient (with connection to solar plant)
n
xxxxxxxxxx
B
1 (Hours / minutes)
B to confirm (the minutes flash)
B and select programme row 20 (Change language);
B to save.
C to exit
B (the hour flashes)
B to edit
B to confirm.
30