DESCRIPTION OF OPERATING MODES
• On: the temperature of the room to heat is comfort, the factory setting is 20 °C (symbols displayed
• Reduced: the temperature of the room to heat is reduced, the factory setting is 16 °C (symbols displayed
• Timed: heating depends on the set time band (symbols displayed
• Off: the boiler start when the room temperature falls below 6°C.
When the boiler operates in the Timed mode, turn the knob B to temporarily adjust the temperature. This modification
remains valid until the subsequent time band change.
The boiler anti-freeze is always active, the boiler ignites when the flow temperature falls below 5 °C. The function operates if the
appliance is electrically powered and there is gas.

4.1.1 ADJUSTING THE REDUCED AMBIENT HEATING TEMPERATURE

To set the Reduced ambient temperature, proceed as follows:
C
B
"Temps / mode CH1"
B
programme row 712 (Reduced temperature) then
B to edit the temperature and
C to return to the previous menu.
Apart from using key A of section 3, the comfort ambient temperature can also be adjusted by editing parameter 710 ,as described
above.
4.2

HOLIDAY PROGRAMME

This function allows the user to choose what ambient temperature value to set during his/her absence (for example, during a
holiday). The minimum anti-freeze temperature or the reduced temperature (programme row 648) can be set. Programme row
641 (Select) features 8 programming levels called Period 1 (8 programmable on/off time bands). When the function is enabled,
the symbol
appears on the display.
The procedure to follow to enable the function and programme the time bands is shown below:
C
Holiday Heating 1
B
programme row 641 ("Preselection")
B
programme row 642.
B to set the start period (642)
• Repeat the same sequence of instructions to set programme row 643 (end of period, the boiler will become operative again
the following day).
• After programming the start and end of the period
temperature anti-freeze or reduced and
• Repeat these three points to set other periods or

5. HOURLY PROGRAMMING

Before proceeding with programming, enable the Timed operating mode (section 4).
Hourly programming in the heating mode ( Time central heating CH1) and in the DHW mode ( Time hot water) is used to set
the automatic operation of the boiler in certain daily time bands and in certain days of the week. The example indicated in the
following figure refers to the daily time band 1 (see below) where a is the operating period at the comfort temperature and b is the
operating period in the reduced mode (section 4). Boiler settings can be adjusted by groups of days or by single days (every
day from Mon to Sun).
PRESET WEEKLY INTERVALS
(Programme row 500 for heating and 560 for DHW)
• Mon - Sun (groups of days)
• Mon - Fri (groups of days)
• Sat - Sun (groups of days)
• Mon - Tue - Wed - Thu - Fri - Sat - Sun (single days)
PRESET DAILY TIME BANDS
(Programme row 514 for heating and 574 for DHW)
• 06:00-08:00 .. 11:00-13:00 .. 17:00-23:00 (example in figure to side)
• 06:00-08:00 .. 17:00-23:00
• 06:00-23:00
7110317.02 (3-10/14)
B.
B to confirm.
B Period 1(flashing)
B
B to set the month
B
programme row 648
B to confirm.
C to return to the previous menu.
32
);
B (the temperature value starts flashing) ;
B and select which one to set (from 1 to 8) then
B and
B to set the day
B
B to set the minimum operating
);
);
B to confirm.