Commissioning The Boiler; Control Panel; Basic Control Panel Settings - Baxi LUNA PLATINUM Instruction Manual For Users And Fitters

Condensing gas wall-hung boilers
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 26

1. COMMISSIONING THE BOILER

To light the boiler correctly, proceed as follows:
• Open the gas tap (yellow, normally positioned under the boiler);
• Check that the hydraulic pressure in the system is correct (section 8);
• Power the boiler;
• The boiler leaves the factory with the CH and DHW circuits disabled. Before enabling these circuits, perform the system
VENTING procedure as described in section 15 SPECIAL FUNCTIONS "Venting function (312)". Then enable the CH and
DHW circuits using the EASY MENU (
qualified technicians.
The boiler control panel can be installed on the wall to manage the temperature of the room to heat.
During initial ignition, the burner may not ignite (causing the boiler to shut down) until any air in the gas pipes is vented. To
re-ignite the boiler, see section 4.

CONTROL PANEL

Key to SYMBOLS
Burner lit
(Power %: 1<70% - 2>70%)
Operating mode: comfort ambient temperature
Operating mode: reduced ambient temperature
(only if installed indoors)
Operating mode in heating:
1 = zone 1 – 2 = zone 2 – 3 = zone 3
Operating mode: DHW enabled
Operating mode: AUTOMATIC
Operating mode: MANUAL
Ambient temperature (°C)
External temperature (°C)
Off: heating and DHW disabled
(only boiler anti-freeze protection is active)
Flue cleaner function enabled
Holiday programme function enabled
Data transmission
(only if the WIRELESS device is connected)
1.1

BASIC CONTROL PANEL SETTINGS

INITIAL IGNITION CONFIGURATION PROCEDURE
When igniting the boiler for the first time, perform the following procedure (the text is written in ENGLISH until the user is requested
to set his/her language as illustrated in sequence A-B-C of the figure indicated below):
B for 5 seconds;
• the Control Panel displays a percentage value from 1 to 100. Data synchronisation takes a few minutes to complete;
• set the language, date and time.
A
) button as described in section 3. These operations must only be performed by
Connection to SOLAR plant
Fault
Fault preventing the burner from lighting
Technical Service Centre call-in
Boiler/system water pressure low
Set unit of measurement (SI/US)
B
29