User Manual Installation Lite Managed Switch GECKO 4TX Installation GECKO Technical support Release 01 07/2014 https://hirschmann-support.belden.eu.com...
Page 2
In addition, we refer to the conditions of use specified in the license contract. You can get the latest version of this manual on the Internet at the Hirschmann product site (www.hirschmann.com). Printed in Germany Hirschmann Automation and Control GmbH Stuttgarter Str.
Contents Safety instructions About this Manual Legend Description General description Device view Power supply Ethernet ports 1.4.1 10/100 Mbit/s twisted pair port Display elements 1.5.1 Device state 1.5.2 Port state Installation Checking the package contents Installing the device onto the DIN rail Wiring the terminal block for the working voltage and grounding Operating the device...
Never start operation with damaged components. The device does not contain any service components. If the device is not functioning correctly, or if it is damaged, turn off the power supply and return the device to Hirschmann for inspection. WARNING UNCONTROLLED MACHINE ACTIONS To avoid uncontrolled machine actions caused by data loss, configure all the data transmission devices individually.
Intended usage Use the product only for the application cases described in the Hirschmann product information, including this manual. Operate the product only according to the technical specifications. See “Technical data” on page 24. Connect to the product only components suitable for the requirements of the specific application case.
The power supply cables used are permitted for the temperature range required by the application case. The power cords are suitable for ambient air temperatures of at least 167 °F (75 °C). The power cord wires are made of copper. ...
Page 8
In accordance with the above-named EU directive(s), the EU conformity declaration will be at the disposal of the relevant authorities at the following address: Hirschmann Automation and Control GmbH Stuttgarter Str. 45-51 72654 Neckartenzlingen Germany Tel.: +49 1805 141538 The product can be used in the industrial sector.
Page 9
FCC note: This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference; (2) this device must accept any interference received, including interference that may cause undesired operation. Appropriate testing has established that this device fulfills the requirements of a class A digital device in line with part 15 of the FCC regulations.
“References” chapter of the configuration user manual. You can find the documentation that is not provided as a printout with your device as a PDF file under “Downloads” at www.hirschmann.com/en/QR/INET-GECKO4TX_en-HB. The Industrial HiVision network management software provides you with additional options for smooth configuration and monitoring: ...
There are convenient options for managing the device. Administer your devices via: a Web browser Network management software (e.g. Industrial HiVision) The Hirschmann network components help you ensure continuous communication across all levels of the company. Installation GECKO Release 01 07/2014...
Page 12
Example Application Redundant data link Redundancy procedure: Rapid Spanning Tree Protocol Control GECKO 4TX Data link Production cell Installation GECKO Release 01 07/2014...
Device view 1 LED display element Device Status 2 3-pin terminal block for the supply voltage and the grounding 3 Ports 1 ... 4 10/100 Mbit/s twisted pair ports 4 LED display elements port state Power supply A 3-pin, pluggable terminal block is available for the power supply to the device.
Ethernet ports 1.4.1 10/100 Mbit/s twisted pair port This port is an RJ45 socket. The 10/100 Mbit/s twisted pair port offers you the ability to connect network components according to the IEEE 802.3 10BASE-T/100BASE-TX standard. This port supports: Autonegotiation ...
1.5.1 Device state This LED provides information on the status of the power supply. LED display element for device status Display Color Activity Meaning Power Green Lights up Operating voltage is on None Working voltage is too low 1.5.2 Port state These LEDs display port-related information.
Installation Note: Before installing and starting up the device, read the safety instructions. See “Safety instructions” on page 5. The devices have been developed for practical application in a harsh industrial environment. On delivery, the device is ready for operation. The following steps should be performed to install and configure a device: ...
To mount the device onto a horizontally mounted 35 mm DIN rail according to DIN EN 60715, proceed as follows: Slide the upper snap-in guide of the device into the DIN rail. Slide the bottom part of the device onto the DIN rail. Wiring the terminal block for the working voltage and grounding CAUTION...
Figure Pin assignment on the device Specification of the working voltage +24 V Rated voltage range DC +24 V 12 V ... 24 V Ground connection Voltage range DC incl. maximum tolerances 9,6 V ... 32 V Table 2: 3-pin terminal block pin assignment The working voltage is electrically isolated from the housing.
Connecting data cables Note: In general, adhere to the following recommendations for data cable connections in environments with high electrical interference levels: Keep the length of the data cables as short as possible. When using copper cables, verify that there is a sufficient gap between the power supply cables and the data cables when laid over a long distance.
Click "OK". The Web browser shows the window with the graphical user interface. You will find further information on configuring the device in the “Configuration” user manual on the Internet on the Hirschmann product pages (www.hirschmann.com/en/QR/INET-GECKO4TX_en-HB). Installation GECKO Release 01 07/2014...
Monitoring the ambient air temperature Operate the device below the specified maximum ambient air temperature exclusively. See “General technical data” on page 24. The ambient air temperature is the temperature of the air at a distance of 2 in (5 cm) from the device. It depends on the installation conditions of the device, e.g.
Hirschmann are continually working on improving and developing their software. Check regularly whether there is an updated version of the software that provides you with additional benefits. You find information and software downloads on the Hirschmann product pages on the Internet (www.hirschmann.com). ...
Disassembly To prepare the deinstallation, you proceed as follows: Disconnect the data cables. Disable the working voltage. Remove the power connector from the device. Disconnect the grounding. To remove the device from the DIN rail, you proceed as follows: ...
Technical data General technical data Dimensions See “Dimension drawings” on page 25. W × H × D Weight 0.23 lb (103 g) Power supply Safety extra-low voltage (SELV) Relevant for North America: Class 2 Rated voltage range DC 12 V ...
Page 26
EMC and immunity EMC interference emission Radiated emission EN 55022 Class A FCC 47 CFR Part 15 Class A EN 61000-6-4 Fulfilled Conducted emission EN 55022 DC supply connection Class A FCC 47 CFR Part 15 DC supply connection Class A EN 61000-6-4 DC supply connection...
1 × Mounting instruction Order number Device Order number GECKO 4TX 942 104-001 Accessories Note: Please note that products recommended as accessories may have characteristics that do not fully correspond to those of the device. This may limit their possible usage in the overall system.
Page 28
Underlying technical standards Designation CSA C22.2 No. 142 Canadian National Standard(s) – Process Control Equipment – Industrial Products EN 55011 Industrial, scientific and medical equipment – Radio-frequency disturbance characteristics – Limits and methods of measurement EN 55022 Information technology equipment – Radio disturbance characteristics – Limits and methods of measurement EN 60950-1 Information technology equipment –...
Further Support Technical Questions For technical questions, please contact any Hirschmann dealer in your area or Hirschmann directly. You will find the addresses of our partners on the Internet at http://www.hirschmann.com Contact our support at https://hirschmann-support.belden.eu.com You can contact us in the EMEA region at ...