CS-E15DD3EW CU-E15DBE / CS-E18DD3EW CU-E18DBE
How to use electronic circuit diagram
TIMER TABLE <INDOOR>
4 way valve abnormality
Outdoor air temp. for Hz No. decision
Anti-dew formation control
Anti-freezing control
Thermo OFF delay
Low pressure control (gas leakage) compressor OFF time
Time delay safety control
Odour timer status shift time
Intake air temp. sampling time
Self diagnosis display time
Auto mode judgement sampling time
24 hours Real Timer
Heating SSHi fan speed shift
Cooling SHi fan speed shift
Hot start forced completion
Auto mode judgement interval
After Hot start / Deice
TIMER TABLE <OUTDOOR>
DC PEAK
Deice detection
Hz lock time
Outdoor fan delay operation control
4 way valve delay operation control
Name
Name
Time
4 min.
30 min.
20 min.
6 min.
3 min.
3 min.
2 min. 58 sec.
20 sec.
90 sec.
20 sec.
120 sec.
2 min.
10 sec.
20 sec.
1 hour
120 min.
30 min.
4 min.
30 min.
2 min.
Time
30 sec.
120 min.
80 min.
40 min.
40 min.
30 sec.
30 sec.
3 min.
84
Test mode
(When test point
Short-circuited)
24 sec.
0 sec.
0 sec.
0 sec.
0 sec.
0 sec.
0 sec.
0 sec.
0 sec.
0 sec.
0 sec.
1 min.
12 sec.
3 sec.
0.4 sec.
3 sec.
12 sec.
Test mode
(When test point
Short-circuited)
3 sec.
24 sec.
16 sec.
8 sec.
8 sec.
0 sec.
3 sec.
18 sec.