2. Heating
Note:
a. UP:
• If move from Lo, the fan speed will be shifted to Maximum 1520 rpm.
• If move from Maximum, the fan speed no change.
• In up zone, 10 rpm is added for every 10s until Maximum 1520 rpm.
b. DOWN:
• The fan speed will be decreased one step every 10 sec. until Minimum 1270 rpm.
c. Current Output Fixed:
• Maintain at present fan speed.
d. Instantaneous Maximum:
• Fan speed will be increased to maximum auto fan speed.
e. Temperature in ( ) is for Powerful Mode operation.
C. Fan Motor Control
1. Motor specification
Phase control motor
D. Deodorizing Control
i. Control condition
Control at cooling/dry operation and auto fan speed.
No Deodorizing Control is performed during ON timer standby operation and during Anti-freezing control prevention.
ii. Operation
The odor status is arranged as below and it is shifted as follow.
* When COMP is ON
* When COMP is OFF
* Start from 4 if the Thermostat is OFF during the start operation.
Odor Status
Status Shift
according to COMP
Status Shift
according
to time (s)
Fan Speed
(Shift to 4 when COMP is OFF)
(Shift to 1 when COMP is ON)
1
2
ON
Cooling
zone
40
50
Dry zone
Cooling
zone
OFF
SSLo
Dry zone
1 → 2 → 3
4 → 5 → 6 → 7 → 6 ←→ 7
3
4
5
30
90
Auto Fan Speed
SSLo
OFF
SLo
21
CS-E15DD3EW CU-E15DBE / CS-E18DD3EW CU-E18DBE
6
7
6.7.6...
OFF
20
90
20.90.20...
SSLo
OFF
SSLo.OFF...
1
ON
ON