11.2. Indoor Unit

11.2.1. SELECTING THE INSTALLATION LOCATION
Take into consideration the following contents when creating the blueprint.
I Indoor unit installation location
• The location should be strong enough to support the main unit without vibration.
• There should not be any heat or steam source nearby.
• Drainage should be easy. Avoid locating the drain port close to ditches (domestic wastewater).
• Avoid locations above entrances and exits.
• Do not block the air intake and discharge passages.
• Select the location that enables the cool and warm air to spread out to the entire room.
• Locate the indoor unit at least 1 m or more away from a TV, radio, wireless appliance, antenna cable and fluorescent light,
and 2 m or more away from a telephone.
Note that if the air conditioner is installed near an electronically lit fluorescent light (inverter, rapid start type,
I Remote control mounting location
• Signals may not be transmitted and received correctly
when the remote control is operated while in the holder.
Hold the remote control in your hand to operate the unit.
• Mount the holder at a location that is not exposed to
heat (direct sunlight and stoves, etc.).
11.2.2. TO DRILL A HOLE IN THE WALL AND INSTALL A SLEEVE OF PIPING
1. Insert the piping sleeve to the hole.
2. Fix the bushing to the sleeve.
3. Cut the sleeve until it extrudes about 15 mm from the wall.
Caution
When the wall is hollow, please be sure to use the
sleeve for tube ass'y to prevent dangers caused by
mice biting the connecting cable.
4. Finish by sealing the sleeve with putty or caulking
compound at the final stage.
etc.), it may not receive signals from the remote control.