Order Codes With Process Bus Modules - GE F35 Instruction Manual

Multiple feeder protection system
Hide thumbs Also See for F35:
Table of Contents

Advertisement

ORDER CODES

2.3.2 Order codes with process bus modules

Table 2-6: F35 order codes for horizontal units with process bus
F35
- *
**
BASE UNIT
F35
|
|
CPU
T
|
U
|
V
|
SOFTWARE
00
01
03
04
2
A0
A1
A3
A4
AW
B0
B1
B3
B4
BW
C0
C1
C3
C4
CW
D0
D1
D3
D4
DW
E0
E1
E3
E4
EW
F0
F1
F3
F4
FW
G0
G1
G3
G4
GW
J0
J1
J3
J4
JW
K0
K1
K3
K4
KW
L0
L1
L3
L4
LW
MOUNT/COATING
FACEPLATE/ DISPLAY
POWER SUPPLY
(redundant supply must
be same type as main supply)
PROCESS BUS MODULE
CONTACT INPUTS/OUTPUTS
INTER-RELAY
COMMUNICATIONS
(select a maximum of 1 per unit)
2-10
- * *
*
- F **
- H **
- M **
- P
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
H |
|
|
|
|
A |
|
|
|
|
C
|
|
|
|
D
|
|
|
|
R
|
|
|
|
A
|
|
|
|
P
|
|
|
|
G
|
|
|
|
S
|
|
|
|
B
|
|
|
|
K
|
|
|
|
M
|
|
|
|
Q
|
|
|
|
U
|
|
|
|
L
|
|
|
|
N
|
|
|
|
T
|
|
|
|
V
|
|
|
|
W |
|
|
|
Y
|
|
|
|
I
|
|
|
|
J
|
|
|
|
H
|
|
|
H
|
|
|
L
|
|
|
L
|
|
|
|
81
|
XX
XX
**
- U **
- W/X
**
Full Size Horizontal Mount
|
|
|
Base Unit
|
|
|
RS485 and Three Multi-mode fiber 100Base-FX (SFP with LC)
|
|
|
RS485 and Two Multi-mode fiber 100Base-FX (SFP with LC), One 10/100Base-TX (SFP with RJ45)
|
|
|
RS485 and Three 10/100Base-TX (SFP with RJ45)
|
|
|
No Software Options
|
|
|
Ethernet Global Data (EGD)
|
|
|
IEC 61850
|
|
|
Ethernet Global Data (EGD) and IEC 61850
|
|
|
CyberSentry Lvl 1
|
|
|
CyberSentry Lvl 1 and Ethernet Global Data (EGD)
|
|
|
CyberSentry Lvl 1 and IEC 61850
|
|
|
CyberSentry Lvl 1 and IEC 61850 and Ethernet Global Data (EGD)
|
|
|
CyberSentry Lvl 1 and IEC 61850 and PID controller
|
|
|
IEEE 1588
|
|
|
IEEE 1588 and Ethernet Global Data (EGD)
|
|
|
IEEE 1588 and IEC 61850
|
|
|
IEEE 1588 and IEC 61850 and Ethernet Global Data (EGD)
|
|
|
IEEE 1588 and IEC 61850 and PID controller
|
|
|
Parallel Redundancy Protocol (PRP)
|
|
|
PRP and Ethernet Global Data
|
|
|
PRP and IEC 61850
|
|
|
PRP, Ethernet Global Data, and IEC 61850
|
|
|
PRP, PID controller, and IEC 61850
|
|
|
IEEE 1588 and CyberSentry Lvl 1
|
|
|
IEEE 1588 and CyberSentry Lvl 1 and Ethernet Global Data (EGD)
|
|
|
IEEE 1588 and CyberSentry Lvl 1 and IEC 61850
|
|
|
IEEE 1588 and CyberSentry Lvl 1 and IEC 61850 and Ethernet Global Data (EGD)
|
|
|
IEEE 1588 and CyberSentry Lvl 1 and IEC 61850 and PID controller
|
|
|
IEEE 1588 and PRP
|
|
|
IEEE 1588, PRP, and Ethernet Global Data
|
|
|
IEEE 1588, PRP, and IEC 61850
|
|
|
IEEE 1588, PRP, Ethernet Global Data, and IEC 61850
|
|
|
IEEE 1588, PRP, PID controller, and IEC 61850
|
|
|
PRP and CyberSentry Lvl 1
|
|
|
PRP, CyberSentry Lvl 1, and Ethernet Global Data
|
|
|
PRP, CyberSentry Lvl 1, and IEC 61850
|
|
|
PRP, CyberSentry Lvl 1, Ethernet Global Data, and IEC 61850
|
|
|
PRP, CyberSentry Lvl 1, PID controller, and IEC 61850
|
|
|
IEEE 1588 and PRP
|
|
|
IEEE 1588, PRP, CyberSentry Lvl 1, and Ethernet Global Data
|
|
|
IEEE 1588, PRP, CyberSentry Lvl 1, and IEC 61850
|
|
|
IEEE 1588, PRP, CyberSentry Lvl 1, Ethernet Global Data, and IEC 61850
|
|
|
IEEE 1588, PRP, CyberSentry Lvl 1, PID controller, and IEC 61850
|
|
|
IEC 60870-5-103
|
|
|
IEC 60870-5-103 + EGD
|
|
|
IEC 60870-5-103 + IEC 61850
|
|
|
IEC 60870-5-103 + EGD + IEC 61850
|
|
|
IEC 60870-5-103 + PID controller + IEC 61850
|
|
|
IEEE1588 + PRP + IEC 60870-5-103
|
|
|
IEEE1588 + PRP + IEC 60870-5-103 + EGD
|
|
|
IEEE1588 + PRP + IEC 60870-5-103 + IEC 61850
|
|
|
IEEE1588 + PRP + IEC 60870-5-103 + EGD + IEC 61850
|
|
|
IEEE1588 + PRP + IEC 60870-5-103 + PID controller + IEC 61850
|
|
|
IEC 60870-5-103 + IEEE1588 + PRP + CyberSentry Lvl 1
|
|
|
IEC 60870-5-103 + IEEE1588 + PRP + CyberSentry Lvl 1 + EGD
|
|
|
IEC 60870-5-103 + IEEE1588 + PRP + CyberSentry Lvl 1 + IEC 61850
|
|
|
IEC 60870-5-103 + IEEE1588 + PRP + CyberSentry Lvl 1 + EGD + IEC 61850
|
|
|
IEC 60870-5-103 + IEEE1588 + PRP + CyberSentry Lvl 1 + PID controller + IEC 61850
|
|
|
Horizontal (19" rack)
|
|
|
Horizontal (19" rack) with harsh environmental coating
|
|
|
English display
|
|
|
French display
|
|
|
Russian display
|
|
|
Chinese display
|
|
|
English display with 4 small and 12 large programmable pushbuttons
|
|
|
French display with 4 small and 12 large programmable pushbuttons
|
|
|
Russian display with 4 small and 12 large programmable pushbuttons
|
|
|
Chinese display with 4 small and 12 large programmable pushbuttons
|
|
|
Enhanced front panel with English display
|
|
|
Enhanced front panel with French display
|
|
|
Enhanced front panel with Russian display
|
|
|
Enhanced front panel with Chinese display
|
|
|
Enhanced front panel with English display and user-programmable pushbuttons
|
|
|
Enhanced front panel with French display and user-programmable pushbuttons
|
|
|
Enhanced front panel with Russian display and user-programmable pushbuttons
|
|
|
Enhanced front panel with Chinese display and user-programmable pushbuttons
|
|
|
Enhanced front panel with Turkish display
|
|
|
Enhanced front panel with Turkish display and user-programmable pushbuttons
|
|
|
Enhanced front panel with German display
|
|
|
Enhanced front panel with German display and user-programmable pushbuttons
|
|
|
125 / 250 V AC/DC power supply
|
|
RH
125 / 250 V AC/DC with redundant 125 / 250 V AC/DC power supply
|
|
|
24 to 48 V (DC only) power supply
|
|
RL
24 to 48 V (DC only) with redundant 24 to 48 V DC power supply
|
|
|
Eight-port digital process bus module
XX
XX
XX
No Module
4A
4A
|
4 Solid-State (no monitoring) MOSFET outputs
4B
4B
|
4 Solid-State (voltage with optional current) MOSFET outputs
4C
4C
|
4 Solid-State (current with optional voltage) MOSFET outputs
4D
4D
|
16 Contact inputs with Auto-Burnishing (maximum of three modules within a case)
4L
4L
|
14 Form-A (no monitoring) Latching outputs
67
67
|
8 Form-A (no monitoring) outputs
6A
6A
|
2 Form-A (voltage with optional current) and 2 Form-C outputs, 8 contact inputs
6B
6B
|
2 Form-A (voltage with optional current) and 4 Form-C outputs, 4 contact inputs
6C
6C
|
8 Form-C outputs
6D
6D
|
16 Contact inputs
6E
6E
|
4 Form-C outputs, 8 contact inputs
6F
6F
|
8 Fast Form-C outputs
6G
6G
|
4 Form-A (voltage with optional current) outputs, 8 contact inputs
6H
6H
|
6 Form-A (voltage with optional current) outputs, 4 contact inputs
6K
6K
|
4 Form-C and 4 Fast Form-C outputs
6L
6L
|
2 Form-A (current with optional voltage) and 2 Form-C outputs, 8 contact inputs
6M
6M
|
2 Form-A (current with optional voltage) and 4 Form-C outputs, 4 contact inputs
6N
6N
|
4 Form-A (current with optional voltage) outputs, 8 contact inputs
6P
6P
|
6 Form-A (current with optional voltage) outputs, 4 contact inputs
6R
6R
|
2 Form-A (no monitoring) and 2 Form-C outputs, 8 contact inputs
6S
6S
|
2 Form-A (no monitoring) and 4 Form-C outputs, 4 contact inputs
6T
6T
|
4 Form-A (no monitoring) outputs, 8 contact inputs
6U
6U
|
6 Form-A (no monitoring) outputs, 4 contact inputs
6V
6V
|
2 Form-A outputs, 1 Form-C output, 2 Form-A (no monitoring) latching outputs, 8 contact inputs
2A
C37.94SM, 1300 nm single-mode, ELED, 1 channel single-mode
2B
C37.94SM, 1300 nm single-mode, ELED, 2 channel single-mode
2E
Bi-phase, single channel
2F
Bi-phase, dual channel
2G
IEEE C37.94, 820 nm, 128 kbps, multimode, LED, 1 Channel
2H
IEEE C37.94, 820 nm, 128 kbps, multimode, LED, 2 Channels
F35 MULTIPLE FEEDER PROTECTION SYSTEM – INSTRUCTION MANUAL
CHAPTER 2: PRODUCT DESCRIPTION

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents