ORDER CODES
T60
- * **
POWER SUPPLY
ENHANCED DIAGNOSTICS CT/VT
DSP
(requires all DSP to be enhanced
diagnostic)
CONTACT INPUTS/OUTPUTS
2
TRANSDUCER
INPUTS/OUTPUTS
(select a maximum of 3 per unit)
INTER-RELAY
COMMUNICATIONS
(select a maximum of 1 per unit)

2.3.2 Order codes with process bus modules

Table 2-6: T60 order codes for horizontal units with process bus
T60
- * **
BASE UNIT
T60
|
|
CPU
T |
U |
V |
SOFTWARE
00
01
03
04
06
07
10
11
20
21
22
23
33
34
A0
A1
A3
2-14
- * *
* - F **
- H **
- M **
- P/R **
H
|
|
|
L
|
|
|
XX
|
XX
8L
|
8L
8M
|
8M
8N
|
8N
8R
|
8R
XX
XX
4A
4A
4B
4B
4C
4C
4D
4D
4L
4L
67
67
6A
6A
6B
6B
6C
6C
6D
6D
6E
6E
6F
6F
6G
6G
6H
6H
6K
6K
6L
6L
6M
6M
6N
6N
6P
6P
6R
6R
6S
6S
6T
6T
6U
6U
6V
6V
5A
5A
5C
5C
5D
5D
5E
5E
5F
5F
- * *
* - F **
- H **
- M **
- P **
| |
|
|
|
|
| |
|
|
|
|
| |
|
|
|
|
| |
|
|
|
|
| |
|
|
|
|
| |
|
|
|
|
| |
|
|
|
|
| |
|
|
|
|
| |
|
|
|
|
| |
|
|
|
|
| |
|
|
|
|
| |
|
|
|
|
| |
|
|
|
|
| |
|
|
|
|
| |
|
|
|
|
| |
|
|
|
|
| |
|
|
|
|
| |
|
|
|
|
| |
|
|
|
|
| |
|
|
|
|
| |
|
|
|
|
Reduced Size Vertical Mount (see note regarding P/R slot below)
|
125 / 250 V AC/DC power supply
|
24 to 48 V (DC only) power supply
|
No DSP module (slots M and U only)
|
Standard 4CT/4VT with enhanced diagnostics
|
Sensitive Ground 4CT/4VT with enhanced diagnostics
|
Standard 8CT with enhanced diagnostics
|
Sensitive Ground 8CT with enhanced diagnostics
XX
No Module
4A
4 Solid-State (no monitoring) MOSFET outputs
4B
4 Solid-State (voltage with optional current) MOSFET outputs
4C
4 Solid-State (current with optional voltage) MOSFET outputs
4D
16 Contact inputs with Auto-Burnishing (maximum of three modules within a case)
4L
14 Form-A (no monitoring) Latching outputs
67
8 Form-A (no monitoring) outputs
6A
2 Form-A (voltage with optional current) and 2 Form-C outputs, 8 contact inputs
6B
2 Form-A (voltage with optional current) and 4 Form-C outputs, 4 contact inputs
6C
8 Form-C outputs
6D
16 Contact inputs
6E
4 Form-C outputs, 8 contact inputs
6F
8 Fast Form-C outputs
6G
4 Form-A (voltage with optional current) outputs, 8 contact inputs
6H
6 Form-A (voltage with optional current) outputs, 4 contact inputs
6K
4 Form-C and 4 Fast Form-C outputs
6L
2 Form-A (current with optional voltage) and 2 Form-C outputs, 8 contact inputs
6M 2 Form-A (current with optional voltage) and 4 Form-C outputs, 4 contact inputs
6N 4 Form-A (current with optional voltage) outputs, 8 contact inputs
6P
6 Form-A (current with optional voltage) outputs, 4 contact inputs
6R
2 Form-A (no monitoring) and 2 Form-C outputs, 8 contact inputs
6S
2 Form-A (no monitoring) and 4 Form-C outputs, 4 contact inputs
6T
4 Form-A (no monitoring) outputs, 8 contact inputs
6U
6 Form-A (no monitoring) outputs, 4 contact inputs
6V
2 Form-A outputs, 1 Form-C output, 2 Form-A (no monitoring) latching outputs, 8 contact inputs
5A
4 DCmA inputs, 4 DCmA outputs (only one 5A module is allowed)
5C
8 RTD inputs
5D
4 RTD inputs, 4 DCmA outputs (only one 5D module is allowed)
5E
4 RTD inputs, 4 DCmA inputs
5F
8 DCmA inputs
2A
C37.94SM, 1300 nm single-mode, ELED, 1 channel single-mode
2B
C37.94SM, 1300 nm single-mode, ELED, 2 channel single-mode
2E
Bi-phase, single channel
2F
Bi-phase, dual channel
2G
IEEE C37.94, 820 nm, 128 kbps, multimode, LED, 1 Channel
2H
IEEE C37.94, 820 nm, 128 kbps, multimode, LED, 2 Channels
2I
Channel 1 - IEEE C37.94, MM, 64/128 kbps; Channel 2 - 1300 nm, single-mode, Laser
2J
Channel 1 - IEEE C37.94, MM, 64/128 kbps; Channel 2 - 1550 nm, single-mode, Laser
72
1550 nm, single-mode, Laser, 1 Channel
73
1550 nm, single-mode, Laser, 2 Channel
74
Channel 1 - RS422; Channel 2 - 1550 nm, single-mode, Laser
75
Channel 1 - G.703; Channel 2 - 1550 nm, Single-mode Laser
76
IEEE C37.94, 820 nm, 64 kbps, multimode, LED, 1 Channel
77
IEEE C37.94, 820 nm, 64 kbps, multimode, LED, 2 Channels
7A
820 nm, multimode, LED, 1 Channel
7B
1300 nm, multimode, LED, 1 Channel
7C
1300 nm, single-mode, ELED, 1 Channel
7D
1300 nm, single-mode, Laser, 1 Channel
7E
Channel 1 - G.703; Channel 2 - 820 nm, multimode
7F
Channel 1 - G.703; Channel 2 - 1300 nm, multimode
7G
Channel 1 - G.703; Channel 2 - 1300 nm, single-mode ELED
7H
820 nm, multimode, LED, 2 Channels
7I
1300 nm, multimode, LED, 2 Channels
7J
1300 nm, single-mode, ELED, 2 Channels
7K
1300 nm, single-mode, Laser, 2 Channels
7L
Channel 1 - RS422; Channel 2 - 820 nm, multimode, LED
7M Channel 1 - RS422; Channel 2 - 1300 nm, multimode, LED
7N Channel 1 - RS422; Channel 2 - 1300 nm, single-mode, ELED
7P
Channel 1 - RS422; Channel 2 - 1300 nm, single-mode, Laser
7Q Channel 1 - G.703; Channel 2 - 1300 nm, single-mode Laser
7R
G.703, 1 Channel
7S
G.703, 2 Channels
7T
RS422, 1 Channel
7W RS422, 2 Channels
- U **
- W/X **
Full Size Horizontal Mount
|
|
|
Base Unit
|
|
|
RS485 and Three Multi-mode fiber 100Base-FX (SFP with LC)
|
|
|
RS485 and Two Multi-mode fiber 100Base-FX (SFP with LC), One 10/100Base-TX
(SFP with RJ45)
|
|
|
RS485 and Three 10/100Base-TX (SFP with RJ45)
|
|
|
No Software Options
|
|
|
Ethernet Global Data (EGD)
|
|
|
IEC 61850
|
|
|
Ethernet Global Data (EGD) and IEC 61850
|
|
|
Phasor Measurement Unit (PMU)
|
|
|
IEC 61850 communications and Phasor Measurement Unit (PMU)
|
|
|
Synchrocheck
|
|
|
Synchrocheck and IEC 61850
|
|
|
Six windings
|
|
|
Six windings and Ethernet Global Data (EGD) protocol
|
|
|
Six windings and IEC 61850 protocol
|
|
|
Six windings, Ethernet Global Data (EGD) protocol, and IEC 61850 protocol
|
|
|
Phasor Measurement Unit (PMU) and synchrocheck
|
|
|
Phasor Measurement Unit (PMU), IEC 61850 protocol, and synchrocheck
|
|
|
CyberSentry Lvl 1
|
|
|
CyberSentry Lvl 1 and Ethernet Global Data (EGD)
|
|
|
CyberSentry Lvl 1 and IEC 61850
T60 TRANSFORMER PROTECTION SYSTEM – INSTRUCTION MANUAL
CHAPTER 2: PRODUCT DESCRIPTION

Hide quick links:

Advertisement

Table of Contents
loading