Technical data

Design data
Dimensions (W x H x D) (in mm)
Weight (in kg)
Cooling method
Degree of protection
Electrical data
Supply voltage
Ripple
Current consumption from 24 V
Non-periodic overvoltage
Starting current, total
Power loss
Interference immunity in accordance with
EN 61800-3
Overvoltage category
Degree of pollution
Transport and storage conditions
Temperature
Vibration resistance (transport)
Shock resistance (transport)
Free fall
Relative humidity
Atmospheric pressure
Ambient operating conditions
Temperature
Atmospheric pressure
Vibration resistance (in operation)
Shock resistance (in operation)
Lithium battery
Rated output voltage
Mechanical Installation Manual
Operating Instructions, 12/2012, 6FC5397-2EP10-0BA0
PPU
420 x 200 x 104
3.06
Self-cooling
Front side: IP54
Back side: IP20
24 V DC (permissible range: 20.4...28.8 V)
3.6 Vpp
Basic configuration
typically 1.5 A (inputs/outputs open)
35 V (500 ms duration, 50 s recovery time)
5 A
max. 50 W
≥ 20 μs
3
2
-20 °C to +60 °C
5 Hz~9 Hz: 3.5 mm
9 Hz~200 Hz: 1g
10 g peak value, 6 ms duration
100 shocks in each of the 3 axes vertical to one another
< 1m
5% to 95%, without condensation
1060 hPa to 700 hPa (corresponds to an altitude of 3,000 m)
0 °C to 45 °C
From 1080 hPa to 795 hPa
10 Hz~58 Hz: 0.35 mm
58 Hz~200 Hz: 1g
10 g peak value, 6 ms duration
6 shocks in each of the 3 axes vertical to each other
3 V
MCP
420 x 120 x 58
0.86
Self-cooling
Front side: IP54
Back side: IP00
3.6 Vpp
5 A
max. 5 W
≥ 20 μs
3
2
-20 °C to +60 °C
5 Hz~9 Hz: 3.5 mm
9 Hz~200 Hz: 1g
<1m
5% to 95%, without condensation
From 1080 hPa to 795 hPa
10 Hz~58 Hz: 0.35 mm
58 Hz~200 Hz: 1g
-
4
29

Advertisement

Table of Contents
loading

Table of Contents