Graco 224342 Instructions - Parts Manual page 23

Ratio monark
Table of Contents

Advertisement

Category
Maximum fluid working pressure
Maximum air input pressure
Pump cycles per 1 gallon (3.8 liters)
Maximum recommended pump speed for continuous
operation
Maximum flow at continuous duty
Recommended speed for optimum pump life
Air consumption
Weight
Wetted parts
KEY:
Fluid Outlet Pressure – Black Curves
Air Consumption – Gray Curves
cycles per min
psi
bar
liters/min
To find Fluid Outlet Pressure (bar/psi) at a specific fluid flow (lpm/
gpm) and operating air pressure (bar/psi):
1. Locate desired flow along bottom of chart.
2. Follow vertical line up to intersection with selected fluid outlet
pressure curve (black). Follow left to scale and read fluid outlet
pressure.
Technical Data
24
600
42
500
35
A
400
B
28
A
300
B
21
C
C
200
14
D
D
100
7
0
0
1
gpm
3.8
FLUID FLOW (TEST FLUID: NO 10 MOTOR OIL)
5:1 Monark
Data
600 psi (4.2 MPa, 42 bar)
120 psi (0.8 MPa, 8.4 bar)
24
60 cycles/min
2.5 gallon (9.46 liters) at 60 cycles/min
15–25 cycles/min; 0.63–1.04 gpm (2.38–3.94 liters/min)
approx. 8.2 scfm (0.23 m
at 100 psi (0.7 MPa, 7 bar) air pressure
approx. 20 lb (9 kg)
AISI 302, 303, 304, 316, and 17–4 PH grades of
Stainless Steel; Chrome Plating; PTFE; Ultra–High
Molecular Weight Polyethylene
A
120 psi (0.8 MPa, 8.4 bar) air pressure
B
100 psi (0.7 MPa, 7 bar) air pressure
C
70 psi (0.5 MPa, 4.9 bar) air pressure
D
40 psi (0.3 MPa, 2.8 bar) air pressure
48
72
2
3
7.6
11.4
To find Pump Air Consumption (m#/min or scfm) at a specific fluid
flow (lpm/gpm) and operating air pressure (bar/psi):
1. Locate desired flow along bottom of chart.
2. Follow vertical line up to intersection with selected air consump-
tion curve (gray). Follow right to scale and read air consumption.
3
/min) at 1 gpm (3.8 liters/min)
96
120
scfm
m#/min
20
0.560
16
0.448
12
0.336
8
0.224
4
0.112
4
5
15.2
19.0
308116
23

Advertisement

Table of Contents
loading

This manual is also suitable for:

224343

Table of Contents