Honeywell Acuix - BBV Rx10X Installation Manual

Multi protocol dome interface receiver
Table of Contents

Advertisement

Protocol 15
Variable speed Pan/Tilt.
Zoom/Focus, Auto focus following a Zoom In/Out.
16 Full scene presets.
2 preset patrols.
Slow preset tour. Started by pressing AUTOPAN
Program up to 16 privacy zones
Additional commands:
AUTOPAN: Pressing the AUTOPAN key will run the domes preset tour at slow speed between the patrol 1 preset position.
Iris Open/Close is menu Enter/Exit.
Honeywell Acuix Dome
DOME Menu
(Toggle Mono/Colour)
(Auto Mono/Colour)
Reset dome parameters
The dome and Rx10X are linked using RS485 for control and video for the camera signal.
RS485 control of dome using the following connections:
Description
Dome Connection
RS485 Data +
RS485 Data -
Notes:
The dome address must be set at address 1 for all the cameras that are controlled using aRx10X. This is done in the Acuix by
setting SW4 to just 1 ON. Select VCL protocol by setting SW2 to 3 ON, rest OFF and SW3 to 1,2,8 ON, rest OFF. Check with
the dome manual if you have any doubts.
1 2 3 4 5 6 7 8
If the slow preset tour is running, start patrol 1 & 2 is inhibited. A manual goto preset and lens control will stop the tour leaving
the AUTOPAN led on until the next manual pan command.
Options Function
Option 1 Enable datum mode goto preset 1 after 5 minutes if inactivity.
Rx10X installation manual V3.02

Honeywell Acuix

Using VCL485
Rx10X
DATA +
J6/5
-
J6/4
DATA
Gnd
J6/3
J6/2
J6/1
SW2
ON
ON
1 2 3 4 5 6 7 8
Tx40X
Tx1000
'#' 1
'#' WASH
'#' 2
'#' WIPE
'#' 3
'#' AUTOPAN
'#' 4
'#' LIGHTS
SW3
SW4
ON
1 2 3 4 5 6 7 8
Tx1500
1 '#'
2 '#'
3 '#'
4 '#'
Page 20