BBV Rx10X Installation Manual

BBV Rx10X Installation Manual

Multi protocol dome interface receiver

Advertisement

Rx10X Range
Multi Protocol Dome Interface Receiver
Installation
Guide
Rx10X
Rx10X/AL
Rx10X/WBX
Rx10X/24/WBX
Building Block Video Ltd.,
17 Apex Park,
Diplocks Industrial Estate,
Hailsham, East Sussex, BN27 3JU UK.
Tel: +44(0)1323 842727
Fax: +44(0)1323 842728
Support: +44(0)1323 444600
www.bbvcctv.com
Version 3.02 software V14

Advertisement

Table of Contents
loading

Summary of Contents for BBV Rx10X

  • Page 1 Rx10X Range Multi Protocol Dome Interface Receiver Installation Guide Rx10X Rx10X/AL Rx10X/WBX Rx10X/24/WBX Building Block Video Ltd., 17 Apex Park, Diplocks Industrial Estate, Hailsham, East Sussex, BN27 3JU UK. Tel: +44(0)1323 842727 Fax: +44(0)1323 842728 Support: +44(0)1323 444600 www.bbvcctv.com Version 3.02 software V14...
  • Page 2 Rx10X installation manual V3.02 Page 2...
  • Page 3: Table Of Contents

    Fig 5. COAX Control Fig 6. 20mA Control Fig 7.Rx10X/AL Alarm Connections Fig 8.Rx10X/WBX Auxiliary Connections Rx10X in PC TEST MODE – Please read note Fig 9. test mode 6. Dome specific information Dennard 2040, 2050, 2055 & 2060 GENIE ASD276 & ASD376 Honeywell Acuix JVC TK-C655B, 675B, TK-C675E, TK-C675BE &...
  • Page 4: Pre-Installation Checks And Safety Procedures

    Never spill liquid of any kind on or inside the unit. Servicing - Servicing of the unit should only be undertaken by qualified service personnel, as opening or removing covers may expose you to dangerous voltages or other hazards. Rx10X installation manual V3.02 Page 4...
  • Page 5: Important Safety Precautions 4

    Safety during installation or servicing - Particular care should be taken to isolate the dome in order to prevent operation while engineering work is being carried out on the Rx10X. Adhere to safety standards - All normal safety precautions as laid down by British Standards and the Health and Safety at Work Act should be observed.
  • Page 6: Introduction

    2. INTRODUCTION GENERAL The Rx10X telemetry interface is designed to allow control of a variety of integrated dome cameras using BBV’s range of up-the-coax telemetry transmitters. Rx10X TECHNICAL SPECIFICATION Power Requirements: Rx10X 12 – 36Vdc 24Vac from the dome supply(excluding the Dennard dome) This unit is supplied with a 2.1mm Jack power fly lead.
  • Page 7: Rx10X Technical Specification 6

    Dimensions: Rx10X Rx10X/AL Rx10X/WBX Rx10X/24/WBX Length 69mm 102mm 365mm 365mm Width 58mm 113mm 180mm 180mm Height 36mm 34mm 100mm 100mm 99 grams 152grams 1.27Kg 2.54 Kg Weight Temperature range: -10° Celsius to +40°Celsius Rx10X installation manual V3.02 Page 7...
  • Page 8: Cable Connection Method

    BNCs 5 way screw Video to terminal plug controller 2.1mm coaxial power connector. This product is not polarity sensitive Fig 1. Cable connection method CABLING RECOMMENDATIONS FOR THE Rx10X INTERFACE. COAX TWISTED PAIR Attenuation Outer External Inner Dielectric Braiding Impedance...
  • Page 9: Installation

    3. INSTALLATION The Rx10X requires all connections to the PCB to be made by the installer, via terminal blocks or by plug and socket. These connections are: power in, video in, video out, and serial data to dome. See Fig.2 below for correct connections.
  • Page 10: Setup

    ‘, to indicate that the value has been entered. It will then show the software version, the protocol & finally the option number. Then you will see a red flashing dot to show the Rx10X is running. Rx10X installation manual V3.02...
  • Page 11: Protocol Selection Table

    Rx10X and you systems particular VISTA transmitter. To enable the Rx10X to go into it’s De-Bug mode you must set it to: Protocol – 0, Mode – 1 If mode 1 is not selected the Rx10X will revert to protocol 1 on reboot Rx10X installation manual V3.02...
  • Page 12: Options & Modes

    Options & Modes Each protocol supports different features which are triggered by selecting different modes in the Rx10X. The following table indicates how to choose the correct mode number. Please refer the dome specific information later in the manual the different mode selects different options to be implemented.
  • Page 13: Diagnostic Aids

    The Rx10X has an in built facility that enables you to test the communications between the Rx10X& the dome. This is done by pressing SW1 and the dome will pan left or press SW3 and the dome will pan right, on releasing the button the dome will stop.
  • Page 14: System Schematic Diagrams

    Sensormatic Pelco Domes Pelco Esprit Vista Powerdome Honeywell Videcon All Dennard Domes Bosch Domes JVC TX_C676 Panasonic DATA 20mA IN GAIN 20mA IN 12 – 36Vdc or 24Vac 12VDC LIFT 100mA 300ohm closed resistance Rx10X installation manual V3.02 Page 14...
  • Page 15: Fig 7.Rx10X/Al Alarm Connections

    Fig 7.Rx10X/AL Alarm Connections PIR or other normally closed alarm input to the Rx10X/AL Dome Power supply LIVE FUSE 230V 50Hz 24V 50Hz 12 – 24 V ac or dc NEUTRAL AAlarm AAlarm DATA IND1 AAlarm AAlarm AGroundA GroundA AAOUTA...
  • Page 16: Fig 8.Rx10X/Wbx Auxiliary Connections

    Fig 8.Rx10X/WBX Auxiliary Connections 24VAC 24VAC 12 – 24 V ac or dc 230V IN PCB11007 Iss1 www.bbvcctv.com Alarm 1 Alarm 2 DATA IND1 Alarm 3 Alarm 4 Ground Ground AOUT AOUT AOUT AOUT RY2A oData + to the domeo...
  • Page 17: Rx10X In Pc Test Mode - Please Read Note

    Rx10X in test mode Protocol - 0 Fig 9.test mode Mode – 1 If mode 1 is not selected the Rx10X will revert to protocol Rx100 TEST P2_V10 BBV CHECKING EEPROM - WAIT 1 on reboot! EE OK...
  • Page 18: Dome Specific Information

    6.DOME SPECIFIC INFORMATION Protocol 08 Dennard 2040, 2050, 2055 & 2060 dome. The Rx10X can not be powered from the same supply as the Dennard dome. Variable speed Pan/Tilt. Zoom/Focus, Auto focus 16 full scene presets (additional presets can be programmed using dome's menu) 2 preset patrols Dennard 2040, 2050, 2055 &...
  • Page 19: Genie Asd276 & Asd376

    Call GROUP1 (preset 151) '#' 4 '#' LIGHTS Pattern Tour 1 playback = press AUTOPAN (preset 131) The dome and Rx10X are linked using RS485 for control and video for the camera signal. RS485 control of dome using the following connections: Description Rx10X...
  • Page 20: Honeywell Acuix

    '#' AUTOPAN 4 ‘#’ Reset dome parameters '#' 4 '#' LIGHTS The dome and Rx10X are linked using RS485 for control and video for the camera signal. RS485 control of dome using the following connections: Description Rx10X Dome Connection RS485 Data +...
  • Page 21: Jvc Tk-C655B, 675B, Tk-C675E, Tk-C675Be & 676

    #1 twice whilst the menu is displayed sends a BACK command. If the #1 command doesn’t work press a focus key before sending #1. Pressing #1 FOUR times within 2 seconds will display the dome’s service menu. Rx10X installation manual V3.02 Page 21...
  • Page 22: Merit Li-Lin Pih-717X/7000/7600/7625

    Option 1: Enable datum mode goto preset 1 after 5 minutes if inactivity. baud rate is 9600 The default baud rate to 2400 Option 2: Force baud rate to 4800 Option 3: Force baud rate to 19200 Option 2 & 3: Force Rx10X installation manual V3.02 Page 22...
  • Page 23: Panasonic Wv-Csr400, Wv-Csr600 & Wv-Csr650

    IMPORTANT: Dome settings: Select dome address 01. Communications must be 19200, N, 8, 1. If dome cannot be controlled, see dome manual section to reset dome to factory default. Options Function Option 1 Enable datum mode goto preset 1 after 5 minutes if inactivity. Rx10X installation manual V3.02 Page 23...
  • Page 24: Panasonic Wv-Cvs 850 & Wv-Cvs 960

    Step 1: Address switches 2, 4 and 5 ON Step 2: Address switches 1, 3, 4 and 5 ON Step 3: Address switches 1 and 8 ON. 4 Way switch 1 ON to select 4 wire, terminated RS485. Rx10X installation manual V3.02 Page 24...
  • Page 25: Pelco Spectra & Esprit (D Protocol) 2400

    OFF = sends a save preset 95 ON = sends a goto preset 95 Option 4: is used to send a goto preset 64 to be used when controlling the COP Dome when 1 # is sent to the Rx10X this supersedes Option 3: Rx10X installation manual V3.02...
  • Page 26: Pelco Spectra & Esprit (P Protocol) 9600

    OFF = sends a save preset 95 ON = sends a goto preset 95 Option 4: is used to send a goto preset 64 when 1 # is sent to the Rx10X. This is to be used when controlling the COP Dome this supersedes Option 3: Option 5 Vista receive mode Rx10X installation manual V3.02...
  • Page 27: Philips Auto Dome (Rs232/485)

    #0. If the dome address is not #0 or #1 then the dome will require reprogramming using a Philips controller or turn on option 2. Rx10X installation manual V3.02 Page 27...
  • Page 28: Sensormatic Ultra Dome 5, 6 & 7 (Rs422 Only)

    Options Function Option 1 Enable datum mode goto preset 1 after 5 minutes if inactivity. Option 1 + 2 both on to start preset patrol after 5 minutes if inactivity. Option 5 Vista receive mode Rx10X installation manual V3.02 Page 28...
  • Page 29: Vcl Microsphere / Obiter Range

    Notes: The dome address must be set at 1 for all the cameras that are controlled using a RX10X. With an Orbiter Gold, set the address to 1 with all switches of DILSW2 ON. Select VCL protocol with all switches of DILSW1 OFF. Check with the dome manual if you have any doubts.
  • Page 30 S2 is used to select control method and video standard. Set to Simplex data S2/3 = ON & VPS with S2/2=OFF. (SW2 1, 5, 6, 7& 8= OFF) For other versions of dome that do not support auto baud rate detect ensure that baud set for 9600. Please check Vicon manual to confirm switch settings. Rx10X installation manual V3.02 Page 30...
  • Page 31: Videconvcp451&Vhcd 860

    Stop Recording '#' 4 '#' LIGHTS Pattern Tour 1 playback = press AUTOPAN The dome and Rx10X are linked using RS485 for control and video for the camera signal. RS485 control of dome using the following connections: Description Rx10X Dome Connection...
  • Page 32: Videconvhsd 870

    Pattern Tour 1 playback = press AUTOPAN (preset 131) The dome and Rx10X are linked using RS485 for control and video for the camera signal. RS485 control of dome using the following connections:...
  • Page 33: Vista Power Dome

    J6/1 Notes: The dome address must be set at 1 for all the cameras that are controlled using a Rx10X. Check with the dome manual to enable the correct setup of the dome. If the learned tour playback is running, start patrol 1 is inhibited.
  • Page 34: Troubleshooting

    Check the two red 7 segment LED displays mounted on the top PCB on interface see page 10. If the problem persists having followed the above steps, technical assistance can be received from Building Block Video. Tel: +44 (0)1323 444600 Rx10X installation manual V3.02 Page 34...
  • Page 35 Rx10X installation manual V3.02 Page 35...
  • Page 36 BBV product, and return it FREEPOST to BBV: BBV 3 Year Warranty If this card is returned with the serial number of the product and the Installation company details BBV will extend the warranty period from 12 Months to 36 Months. Number of Units, Start Serial No.

This manual is also suitable for:

Rx10x/alRx10x/24/wbxRx10x/wbx

Table of Contents