Using the Rollover-Protection System
(ROPS)
•
Keep the roll bar in the raised and locked position and
use the seat belt when operating the machine.
•
Be certain that the seat belt can be released quickly in
the event of an emergency.
•
Be aware there is no rollover protection when the roll
bar is down.
•
Check the area to be mowed and never fold the ROPS in
areas where there are slopes, drop offs or water.
•
Lower the rollbar only when absolutely necessary. Do not
wear the seat belt with the roll bar folded down.
•
Check carefully for overhead clearances (i.e. branches,
doorways, electrical wires) before driving under any
objects and do not contact them.
Model 74846
Sound Power
This unit has a guaranteed sound power level of 105 dBA,
which includes an Uncertainty Value (K) of 1 dBA.
Sound power level was determined according to the
procedures outlined in ISO 11094.
Sound Pressure
This unit has a sound pressure level at the operator's ear of 92
dBA, which includes an Uncertainty Value (K) of 1 dBA.
Sound power level was determined according to the
procedures outlined in EN ISO 5395:2013.
Hand-Arm Vibration
Measured vibration level for left hand = 4.8 m/s2
Measured vibration level for right hand = 4.4 m/s2
Uncertainty Value (K) = 2.4 m/s2
Measured values were determined according to the procedures
outlined in EN ISO 5395:2013.
Whole Body Vibration
Measured vibration level = 0.39 m/s2
Uncertainty Value (K) = 0.19 m/s2
Measured values were determined according to the procedures
outlined in EN ISO 5395:2013.
Model 74848
Sound Power
This unit has a guaranteed sound power level of 105 dBA,
which includes an Uncertainty Value (K) of 1 dBA.
Sound power level was determined according to the
procedures outlined in ISO 11094.
Sound Pressure
This unit has a sound pressure level at the operator's ear of 92
dBA, which includes an Uncertainty Value (K) of 1 dBA.
Sound power level was determined according to the
procedures outlined in EN ISO 5395:2013.
Hand-Arm Vibration
Measured vibration level for left hand = 5.8 m/s2
Measured vibration level for right hand = 3.6 m/s2
Uncertainty Value (K) = 2.3 m/s2
Measured values were determined according to the procedures
outlined in EN ISO 5395:2013.
Whole Body Vibration
Measured vibration level = 0.45 m/s2
Uncertainty Value (K) = 0.22 m/s2
Measured values were determined according to the procedures
outlined in EN ISO 5395:2013.