Model 74846; Model 74848 - Toro TITAN ZX 4800 Operator's Manual

Zero-turn-radius riding mower model no. 74846; model no. 74848
Hide thumbs Also See for TITAN ZX 4800:
Table of Contents

Advertisement

Using the Rollover-Protection System
(ROPS)
Keep the roll bar in the raised and locked position and
use the seat belt when operating the machine.
Be certain that the seat belt can be released quickly in
the event of an emergency.
Be aware there is no rollover protection when the roll
bar is down.
Check the area to be mowed and never fold the ROPS in
areas where there are slopes, drop offs or water.
Lower the rollbar only when absolutely necessary. Do not
wear the seat belt with the roll bar folded down.
Check carefully for overhead clearances (i.e. branches,
doorways, electrical wires) before driving under any
objects and do not contact them.

Model 74846

Sound Power
This unit has a guaranteed sound power level of 105 dBA,
which includes an Uncertainty Value (K) of 1 dBA.
Sound power level was determined according to the
procedures outlined in ISO 11094.
Sound Pressure
This unit has a sound pressure level at the operator's ear of 92
dBA, which includes an Uncertainty Value (K) of 1 dBA.
Sound power level was determined according to the
procedures outlined in EN ISO 5395:2013.
Hand-Arm Vibration
Measured vibration level for left hand = 4.8 m/s2
Measured vibration level for right hand = 4.4 m/s2
Uncertainty Value (K) = 2.4 m/s2
Measured values were determined according to the procedures
outlined in EN ISO 5395:2013.
Whole Body Vibration
Measured vibration level = 0.39 m/s2
Uncertainty Value (K) = 0.19 m/s2
Measured values were determined according to the procedures
outlined in EN ISO 5395:2013.

Model 74848

Sound Power
This unit has a guaranteed sound power level of 105 dBA,
which includes an Uncertainty Value (K) of 1 dBA.
Sound power level was determined according to the
procedures outlined in ISO 11094.
Sound Pressure
This unit has a sound pressure level at the operator's ear of 92
dBA, which includes an Uncertainty Value (K) of 1 dBA.
Sound power level was determined according to the
procedures outlined in EN ISO 5395:2013.
Hand-Arm Vibration
Measured vibration level for left hand = 5.8 m/s2
Measured vibration level for right hand = 3.6 m/s2
Uncertainty Value (K) = 2.3 m/s2
Measured values were determined according to the procedures
outlined in EN ISO 5395:2013.
Whole Body Vibration
Measured vibration level = 0.45 m/s2
Uncertainty Value (K) = 0.22 m/s2
Measured values were determined according to the procedures
outlined in EN ISO 5395:2013.
7