Panasonic BB-HNP15 Operating Instructions Manual page 32

Network camera recorder with viewer software
Hide thumbs Also See for BB-HNP15:
Table of Contents

Advertisement

Operating Instructions
Setting
Alarm enable
condition
Before Detected/
After Detected
Executing
Commands for
Detection
Note
Configure alarm/sensor detection after an alarm/sensor has been attached to
the camera.
Setting alarm/sensor detection without an alarm/sensor causes a malfunction.
32
Specify Alarm enable condition ([Rising : GND to Open (High)]
or [Falling : Open (High) to GND]).
• Specify the alarm enable condition after checking the alarm
specification.
• [Rising : GND to Open (High)] is selected automatically
when [Sensor] is selected.
Specify the time before an alarm/sensor is detected or after an
alarm/sensor is detected.
You can specify commands that execute for alarm detection.
You can configure commands in [Detection Commands] page
(see page 33).
Description

Advertisement

Table of Contents
loading

Table of Contents