Pioneer YN020GMFI22M2D Installation Manual page 15

Dc inverter two,three,four and five zone multi split-type air conditioner heat pump
Hide thumbs Also See for YN020GMFI22M2D:
Table of Contents

Advertisement

Table 8.2: European Regions
Rated Current of
Nominal Cross-Sectional
Appliance (A)
 6
6 - 10
10 - 16
16 - 25
25- 32
32 - 45
b. Using wire strippers, strip the rubber jacket
from both ends of signal cable to reveal
about 15cm (6") of the wires inside.
c. Strip the insulation from the ends of the
wires.
d. Using a wire crimper, crimp terminals at the
ends of the wires.
NOTE: While connecting the wires, please
strictly follow the wiring diagram (found inside
the electrical box cover).
2. Remove the electric cover of the outdoor unit.
If there is no cover on the outdoor unit,
disassemble the bolts from the maintenance
board and remove the protection board.
(See Fig. 8.1)
Fig. 8.1
3. Connect the u-lugs to the terminal blocks
Match the wire colors/labels with the labels on
the terminal block, and firmly screw the terminals
of each wire to its corresponding block position.
4. Clamp down the cable with designated cable
clamp.
Area (mm²)
0.75
1
1.5
2.5
4
6
Cover
Screw
5. Insulate unused wires with electrical tape.
Keep them away from any electrical or metal
parts.
6. Reinstall the cover of the electric control box.
Page 15

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Yn030gmfi22m3dYn040gmfi22m4dYn050gmfi22m5d

Table of Contents