Hobby 65TL Siesta TI Manual page 117

Table of Contents

Advertisement

10-5
Built-in devices
revert back to the lowest setting and heat the water in the
boiler to 60° C. The yellow LED (g) will go out when the
water temperature has been reached.
Heating without regulated water temperature
• Set the rotary switch to operating position (d).
• Turn the rotary button (a) to the desired thermostat setting
(1-5).
The green LED (b) for operation lights up and simulta-
neously displays the setting for the room temperature
selected. The yellow LED (g – warming-up phase for the
water) only lights up at water temperatures below 5°C.
The device will automatically select the performance level
required.
When the room temperature set on the operating panel
has been reached the burner will turn off. The warm air
blower will continue to run at a low rotation speed as long
as the air emission temperature (of the device) is above
40°C. If the boiler is full the water will automatically also
be heated. The water temperature will depend on the heat
produced and the duration of heating required to reach the
room temperature selected.
Heating with drained water system
• Set the rotary switch to operating position (d).
• Turn the rotary button (a) to the desired thermostat setting
(1-5).
The green LED (b) for operation lights up and simultane-
ously displays the setting for the room temperature se-
lected. The yellow LED (g) only lights up if the temperature
of the device is below 5°C. The device will automatically
select the performance level required.
When the room temperature set on the operating panel
has been reached the burner will turn off.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

65fl siesta tiA55 gs siesta akA65 gm siesta ak

Table of Contents