Collective Heating Mode; (Operating Heating Function Mainly, Collective Operation Of Cooling And Heating Operation) - Toshiba MMY-MAP1006FT8(J)P-E Service Manual

Super heat recovery multi-e (multi type) outdoor unit
Hide thumbs Also See for MMY-MAP1006FT8(J)P-E:
Table of Contents

Advertisement

4-6. Collective heating mode

(Operating heating function mainly, collective operation of cooling and heating operation)

Outdoor header unit (MMY-MAP1806FT*)
SV52
FM
SV
PMV1
SV12
SV
TE1
PMV4
TE2
SV
SV11
SV
SV5
SV
TL1
SV6
Fusible
plug
FP
SV3D
Oil
SV
separator
Liquid tank
SV41
SV
TD1
Comp1
SV14
Check joint
SV3E
(Liquid pipe)
PMV
TCS
SVS
SVD
SVSS
SVDD
TC2 TCJ
Heating
Outdoor unit
4-Way valve
ON
SV4(n)
OFF(*1)
SV51
OFF
SV52
OFF
SV6
Control
SV11
ON
SV12
OFF
SV14
ON(*2)
Outdoor Fan
(*1) SV4(n) of stopped compressor (n) = ON
(*2) SV14 of stopped outdoor unit = OFF
(*3) It may be controlled.
The outdoor unit which communication line between indoor and outdoor is connected is the "Header unit".
Other outdoor units are called "Follower units".
Fan
Fan
Fan motor
FM
Fan motor
Right side
TO
Main heat exchanger
Right side sub heat exchanger 2
Right side sub heat exchanger 1
Left side
Main heat exchanger
Left side sub heat exchanger 2
Left side sub heat exchanger 1
4-way
valve
TS1
Low-pressure sensor
Check joint
(Low-pressure)
Check joint (High-pressure)
TS2
High-pressure sensor
Accumlator
SV2
SV
SV42
SV3C
SV
TD2
TK4
High
High
pressure
pressure
SW
SW
Comp2
TK1
TK2
Oil header
TK5
SV3A
SV3B
SV
Balance pipe
Liquid pipe
Discharge gas pipe
Suction gas pipe
PMV
TCS
SVS
SVD
SVSS
SVDD
TC1
TC2
TCJ
Heating
SV3A
Control
Cooling thermo ON
SV3B
Control
SVD
SV3C
Control
SVS
SV3D
Control
SVDD
SV3E
ON
SVSS
PMV1
Control
PMV FS
PMV4
Close(*3)
PMV indoor
Control
High-pressure gas refrigerant
Condensed liquid refrigerant
Evaporative gas refrigerant (Low pressure)
( 32 HP system described in the example of ( 18HP + 14HP ))
Outdoor follower unit (MMY-MAP1406FT*)
SV52
SV
PMV1
PMV4
TE2
SV5
TL1
可溶栓
FP
Liquid tank
(SV14)
Check joint
(Liquid pipe)
PMV
TCS
SVS
SVD
SVSS
SVDD
TC1
TC2
TCJ
TC1
Stop
FS unit / Indoor unit
Heating thermo ON
OFF
SVD
ON
ON
SVS
OFF
OFF
SVDD
OFF
ON
SVSS
OFF
Close
PMV FS
Close
Control
PMV indoor
Control
− 63 −
Fan
FM
Fan motor
Right side
TO
Main heat exchanger
Right side sub heat exchanger
Left side
Main heat exchanger
TE1
Left side sub heat exchanger
SV
SV11
SV
SV
SV6
Check joint (High-pressure)
High-pressure sensor
Accumlator
SV2
SV3D
SV
Oil
SV
separator
SV41
SV42
SV3C
SV
SV
TD1
TD2
TK4
Comp1
Comp2
TK1
TK2
Oil header
SV3E
TK5
0
SV3A
SV3B
SV
PMV
TCS
SVS
SVD
SVSS
SVDD
TC2 TCJ
TC1
Cooling
Stop
SVD
OFF
SVS
OFF
SVDD
OFF
SVSS
ON
PMV FS
Close
PMV indoor
Close
Pressure circuit (High-pressure refrigerant)
Low-pressure circuit (Refrigerant recovery line)
4-way
valve
TS1
Low-pressure sensor
Check joint
(Low-pressure)
TS2