Toshiba MMY-MAP1006FT8(J)P-E Service Manual page 147

Super heat recovery multi-e (multi type) outdoor unit
Hide thumbs Also See for MMY-MAP1006FT8(J)P-E:
Table of Contents

Advertisement

C
O
D
E
N
. o
00
Room temperature (Use to control)
01
Room temperature (Remote controller)
0
2
Indoor suction air temperature (TA)
0
3
n I
d
o
r o
c
l i o
0
4
n I
d
o
r o
c
l i o
0
5
n I
d
o
r o
c
l i o
06
Indoor discharge air temperature (TF)
0
8
n I
d
o
r o
P
M
F3
Filter sign time
Suction temperature of air to air heat
F9
exchanger (TSA)
Outside air temperature (TOA)
FA
0
A
N
. o
f o
c
o
n
0B
Total horsepower of connected indoor units
0
C
N
. o
f o
c
o
n
0
D
T
t o
l a
h
o
s r
E0
Refrigerant leakage detection
CODE No.
U1
U2
U3
High-pressure sensor detention pressure (PD)
10
20
30
Low-pressure sensor detention pressure (PS)
11
21
31
Compressor 1 discharge temperature (TD1)
12
22
32
Compressor 2 discharge temperature (TD2)
13
23
33
Outdoor coil temperature (TE1)
15
25
35
Outdoor coil temperature (TE2)
16
26
36
19
29
39
Outside ambient temperature (TO)
1A
2A
3A
Suction temperature (TS1)
Suction temperature (TS2)
1B
2B
3B
Temperature at liquid side (TL1)
1D
2D
3D
CODE No.
U1
U2
U3
PMV1 opening
50
60
70
PMV3 opening
51
61
71
PMV4 opening
52
62
72
1 fan model : Compressor 1 curent (I1)
53
63
73
2 fan model : Compressor 1 and Outdoor fan 1 current (I1)
1 fan model : Compressor 2 and Outdoor fan 1 current (I2)
54
64
74
2 fan model : Compressor 2 and Outdoor fan 2 current (I2)
56
66
76
Compressor 1 revolutions
57
67
77
Compressor 2 revolutions
Outdoor fan mode
59
69
79
Compressor IPDU 1 heat sink temperature
5A
6A
7A
Compressor IPDU 2 heat sink temperature
5B
6B
7B
Outdoor fan IPDU 1 heat sink temperature
5D
6D
7D
Outdoor fan IPDU 2 heat sink temperature
5E
6E
7E
Outdoor unit horsepower
5F
6F
7F
CODE No.
90
Heating/cooling recovery controlled
91
Pressure release
92
Discharge temperature release
Follower unit release
93
(U2/U3 outdoor units)
* 1 Only a part of indoor unit types is installed with the discharge air temperature sensor. This temperature is not displayed for other types.
*2 When the units are connected to a group, data of the header indoor unit only can be displayed.
*3 The first digit of an CODE No. indicates the outdoor unit number.
*4 The upper digit of an CODE No. -4 indicates the outdoor unit number.
1 , 5 ... U1 outdoor unit (Header unit)
2 , 6 ... U2 outdoor unit (Follower unit 1)
3 , 7 ... U3 outdoor unit (Follower unit 2)
* 5 Only the CODE No. 9* of U1 outdoor unit (Header unit) is displayed.
D
a
a t
n
a
m
e
e t
m
p
e
a r
u t
e r
T (
C
) J
e t
m
p
e
a r
u t
e r
T (
C
) 2
e t
m
p
e
a r
u t
e r
T (
C
) 1
*
1
V
o
p
e
n
n i
g
*1
*1
n
e
c
e t
d
n i
d
o
r o
u
n
s t i
n
e
c
e t
d
o
u
d t
o
r o
u
n
s t i
e
p
o
w
r e
f o
o
u
d t
o
r o
u
n
s t i
Data name
Data name
Data name
D
s i
p
a l
y
f
r o
m
t a
Unit
×1
°C
×1
°C
×
1
°
C
×
1
°
C
[0024]=24°C
×
1
°
C
×
1
°
C
×1
°C
×
1
1 /
0
p
s l
0 [
1
5
0
= ]
1
×1
h
[2500] = 2500h
×1
[0024] = 24℃
×1
×
1
u
n
t i
0 [
0
4
8
= ]
4
×10
HP
[0415]=41.5HP
×
1
u
n
t i
[0003]=3 units
×
1
0
H
P
0 [
4
2
0
= ]
4
[- - - - ]= Not valid
[0000]= Normal
[0001]= Possibility of leakage
Display format
Unit
×100
MPa
[0123] = 1.23MPa
×100
MPa
×1
×1
×1
×1
×1
[0024] = 24℃
×1
×1
×1
Display format
Unit
×1
pls
×1
[0500] = 500pls
pls
×1
pls
×10
A
[0135] = 13.5A
×10
A
×10
rps
[0642] = 64.2rps
×10
rps
×1
[0058] = 58 mode
mode
×1
×1
[0024] = 24℃
×1
×1
×1
[0016] = 16HP
HP
Display format
Unit
0: Normal
[0010]=Heating recovery controlled
1: Recovery controlled
[0001]=Cooling recovery controlled
[0010]=Pressure release controlled
[0001]=Discharge temperature release controlled
0: Normal
[0100]=U2 outdoor unit release controlled
1: Release controlled
[0010]=U3 outdoor unit release controlled
[0001]=U4 outdoor unit release controlled
− 146 −
Remote controller display example
5
0
0
p
s l
8
u
n
s t i
2
H
P
Remote controller display example
Remote controller display example
Remote controller display example

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents