95°C
(203"F)
80-84"C
(176~183°F)
1
2
3
64
i
4
A
8
mm
(0.31
in)
B
1
82°±2°C
(180°±3.6"F)
95°C
(203°F)
THERMOSTAT
DISASSEMBLY
1.
Remove:
Screws
(1)
(mounting
the
cover)
Cover
(2)
O-ring
{3}
Thermostatic
valve
(5)
from housing
(4)
INSPECTION
1.
Inspect:
Thermostatic
valve
(5)
Valve
does
not
open
at
80°C~84°C
(176~183°F)^
Replace.
Inspection steps:
Suspend
the thermostatic valve
in
a vessel.
Place
a
reliable
thermometer
in
water.
Slowly heat
(he water,
Observe
the
thermometer,
while continually
stirring
the
water
.
(1)
Thermometer
(2)
Full
opening temperature
(3)
Start
opening
(4)
Water
(5)
Thermostatic valve
(6)
Vessel
[A]
FULL OPENING
[B]
CLOSE
THERMOSTAT
ASSEMBLY
Performance
"REMOVAL"
operations
in
reverse
order.
1.
Install:
Thermostat
(into
housing)
O-ring
Thermostat cover
2.
Tighten:
Screws
(cover)
Screws
(housing
cover):
10Nm{1.0mkg)
NOTE:
___^__
The
thermostatic vaive
is
sealed
and
its
setting
requires specialized
work.
If
its
accuracy
is in
doubt, replace
it.
A
faulty unit
could
cause
serious
overheating
or
over-coo!ing.
2.
Inspect:
O-ring
Wear/Damage
->
Replace.