Technical Data; Outdoor Data; Data Transmission By 433 Mhz; Data Transmission By Cable - La Crosse Technology WS-3610 Operation Manual

Hide thumbs Also See for WS-3610:
Table of Contents

Advertisement

15

Technical Data

15.1

Outdoor Data:

Transmission Range in Open Field: .... up to. 330 ft max.
Measuring Interval Outdoor Data: ....... every 20 s
Temperature Range: ........................... -40 °F to 139.8 °F (Display "OFL" outside this range)
Resolution:........................................... approx. 0.5 °F
Measuring Range Rel. Humidity:......... 1% to 99%
Resolution:........................................... 1%
Rain Volume Display: .......................... 0 to 39.4 in (1 hr, 24 hrs.)
Resolution:........................................... approx. 0.02 in
Wind Speed ......................................... 0 to 111.8 mph or 1 to 50 m/s
Resolution:........................................... 0.1 m/s
Wind Direction: .................................... Graphic Resolution 22.5 Degrees,
15.2
Data Transmission by 433 MHz Signal:
Measuring Interval Thermo-Hygro Sensor: ......................
128 s (at Wind speed ≤ 6.2 mph) or 32 s (at Wind speed > 6.2 mph, or on Wind Gust display); 10
Min. (if the Base Station does not receive any data after 5 successive attempts all outdoor
displays except the rain amount revert to "---")
15.3

Data Transmission by Cable:

Measuring Interval Thermo-Hygro Sensor: ......... 32 s
15.4

Indoor Data:

Measuring Interval Indoor Data: .......... every 20 s
Temperature Range: ........................... 14.2 °F to 139.8 °F (Display "OFL" outside this range)
Resolution:........................................... approx. 0.5 °F
Measuring Range Rel. Humidity:......... 1% to 99%
Resolution:........................................... 1%
Measuring Range Air Pressure: .......... 8.86 inHg to 32.45 inHg
Resolution:........................................... 0.003 inHg
Alarm Duration:.................................... about 2 minutes
15.5

Power Supply:

Base Station:
Batteries:.............................................. 3 ea. 1.5 V Batteries Type AA, IEC LR6 (Alkaline Batteries
or AC power:........................................ AC Adapter INPUT 120VAC / 60HZ (use only the included
Thermo-Hygro-Sensor:
Batteries:.............................................. 2 ea. 1.5 V Batteries Type C (Alkaline Batteries
or.......................................................... Power provided via Cable from the Base Station by using
15.6

PC Connection:

Wiring:.................................................. COM Port Cable (included)
Data Processing: ................................. by PC only
Software:.............................................. "Heavy Weather Pro 3600" (included)
Storage Intervals: ................................ 1 min through 12 h, settable
Data Volume:
Base Station: ....................................... 1750 Data Sets max. in Ring Buffer EEPROM
PC:....................................................... Volume of Main Memory max.
0 to 98.4 in (last week, last month)
0 to 393.7 in (total volume)
Numeric Resolution Character Format
recommended, Life Cycle without EL backlight approx. 1
year)
AC Adapter. Recommended for PC Connection and
frequent use of EL Backlight)
recommended, Life Cycle approx. 2.5 years)
the AC Adapter
12

Advertisement

Table of Contents
loading

Table of Contents