22
www.aeg.com
5.5 Adjustments
• Always disconnect the appliance from
the electricity supply before making
any adjustment.All gas taps are male
cone type with
5.7 Maintenance
Prior to any maintenance work or
changing parts, disconnect the
appliance from the gas and electricity
power sources.
Replacing the taps
Proceed in the following way when
replacing a tap or the thermostat:
Remove pan supports, burner heads.
Unscrew the burner fixing screws
(four for ultrarapid burner and two for
the other burners)
Pull out the knobs.
Unscrew the fixing screws
which lock the front panel to the front
frame then slip out from the upper
fixing brackets.
Unscrew the fixing screws
which lock the hob at the back and
remove it.
Unscrew the nuts
aluminium pipes and pull out the
thermocouple quick connectors
(fig.13).
Unscrew the screws
lock the crosspieces.
Unscrew the screws
unite the the bridles of the taps to
the front frame.
Make to slip the ramp toward the
fig. 14
(fig.14)
1
2
(fig.14
1
of the gas
2
2
3
(fig.12) which
2
(fig.12) which
1
1
2
back part and unscrew the screws
(fig.13) in order to free the taps.
Change seal each time a tap is
replaced. This will ensure perfect
retention between the tap and part.
Reassemble all the parts following
the same procedure but in the
reverse order.
2
1
fig. 12
1
2
fig.13
1
1
2
3
2

Hide quick links: