5.5 Adjustments
All seal must be replaced by the
technician following any adjustment
or regulation.
The adjustment of the reduce rate
(simmer) must be undertaken only
with burners functioning on natural
gas while in the case of burners
functioning on L.P.G, the screw must
be locked down fully (in clockwise
direction).
"Primary air adjustment" on hob gas
burners is unnecessary.
Taps
All gas taps are male cone type with only
one way of passage.
Adjustment of the "Reduced rate"
position as follows (fig. 10):
Turn the burner on and place the knob
on the "Reduced rate" position (small
flame).
Remove the knob of the tap which is
attached by simply applying pressure
to the rod.
Insert a small screwdriver
top shaft and turn the throttling screw
left or right until flame of the burner
is conveniently regulated to the low
position.
Check that the flame does not go out
when the knob is sharply switched
from the "Full on" to "Reduced rate"
positions.
Attention! This operation can be
carried out also with the front panel
fitted, but if you find some difficulties
to reach the adjustment screw,
remove the front panel unscrewing
the fixing screws, which are positioned
in the inferior part of the same and
make to slip downwards.
Gas information
To tighten some components apply the
following torque forces:
Aluminium pipes to burners, valves,
thermostats: 15 Nm
Thermocouples to top burners cups:
3 Nm
Thermocouples to thermostats: 4 Nm
Push-on connector: 20 Nm
Injectors: 4 Nm
fig. 10
5.6 Conversions
Replacing the injectors
Our burners can be adapted to different
types of gas by simply installing the
injectors suitable for the gas you want
to use.
To change the injectors on the hob,
remove the burner cup and head and
with a 7 mm Ø socket spanner replace
them (fig. 11).
To help the installer, the table in the
"TECHNICAL INFORMATION" section.
into the
2
1
gives the burner nominal heat input,
injector diameter and operating pressure
of the different gas types.
After having replaced the injectors,
it will be necessary to proceed with
burner adjustment as explained in the
previous paragraphs. The technician
must replace any seals after the
adjustments have been made.
fig. 11
ENGLISH
21
2
1

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents