Using The Unit - SPORT ELEC MSPRO4M User Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 13
CHOOSE THE WARM-UP PHASE AND
4
(Only for programs 02 to 07).
the screen proposes a warming-up phase before starting the active phase of the program.
f
f
the WArM-UP PHASE pictogram blinks in the top right corner.
to select it, press
, otherwise press the key and validate
then the ALT / SIM pictogram blinks.
f
f
to select ALT, press the key, then validate
to select SIM, press the key, then validate
If you have selected the warm-up phase, SIM is displayed when starting the program, as the warm-up phase is only in the
simultaneous mode.
the pictogram for the program chosen is lit, the muscle zone(s) chosen blink alternately.
the screen is displayed:
- the battery level,
- the phase duration (countdown in minutes),
- the timer pictogram,
- the ALT or SIM option and warm-up phase if you have selected them.
LAUNCHING THE START - ADjUSTING INTENSITY
5
You must press the
buttons matching the cables to the pads (or to the accessories) for starting a program.
For increasing the intensity level and changing the strength of the stimulation, press 11 times to move to the next level.
the intensity level(s) is/are displayed at the bottom of the screen. Do not start a program if the battery level is low.
the intensity ranges vary during the session according to the program.
Warning! The unit is equipped with a security system that locks the launch of a program if the electrode pads are not
placed correctly on the skin.
PROGRAM PERFORMANCE
6
Use of the
(Clear) key
f
f
During the program, you can press the
the next phase starts unless you have reached the end of the program.
In this case, this key allows returning to selecting the 1
Disconnecting the electrodes during the program
f
f
If an electrode is disconnected, the channel concerned is reset to
During these 30 sec, the electrode(s) can be reconnected, and power restored to the level required.
END OF PROGRAM - STOPPING
7
At the end of the session, the screen proposes to start a new session by blinking the front muscles to select the 1
restart the starting procedure if you wish to continue on another muscle zone.
Otherwise, press the
key to stop.
the unit switches to standby after 5 minutes idle.
III. USING ThE UNIT
GETTING STARTED
Connect each module to the unit by matching the color indicators (photo A page 4).
f
f
note: You can use the device with 1, 2, 3 or 4 modules.
Fix the electrodes to the module(s) using the snap fasteners (photo B page 4).
f
f
POSITIONING OF THE ELECTRODES
remove the plastic backing sheet from the electrodes (photo C page 4).
f
f
Moisten them by spreading a few drops of water onto the adhesive gel using your fingertips and wait 2 minutes (photo D page 4).
Position the electrode(s) onto your body.
f
f
note: the electrodes are for personal use. For hygiene reasons, they must always be used by the same person.
16
/
OPTION
(it disappears from the screen).
.
key to cancel the ongoing phase.
muscle zone (as at normal end of program).
st
and blinks for 30 sec, before returning to a fixed
.
muscle zone.
st

Advertisement

Table of Contents
loading

Table of Contents