Martin MAC III AirFX User Manual page 55

Hide thumbs Also See for MAC III AirFX:
Table of Contents

Advertisement

Short code
Full-text message
FAN
CMY FAN ERROR
FAN
TOP FAN ERROR
FAN
MAINBOARD FAN 1ERROR
FAN
POWER FAN 1 ERROR
FAN
POWER FAN 2 ERROR
FBEP
PAN FEEDBACK ERROR
Unable to correct pan position
FBET
TILT FEEDBACK ERROR
Unable to correct tilt position
FOER
FOCUS ERROR
FUSB
FORCED USB UPLOAD ENABLED
The fixture has been started in forced upload mode (the Escape button was held during power up).
G11M
GOBO WHEEL GOBO 1 MISSING
The gobo is not installed, faulty, or operating in extremely cold temperatures. Instal, replace or allow
the gobo to warm up.
G12M
GOBO WHEEL GOBO 2 MISSING
The gobo is not installed, faulty, or operating in extremely cold temperatures. Instal, replace or allow
the gobo to warm up.
G13M
GOBO WHEEL GOBO 3 MISSING
The gobo is not installed, faulty, or operating in extremely cold temperatures. Instal, replace or allow
the gobo to warm up.
G14M
GOBO WHEEL GOBO 4 MISSING
The gobo is not installed, faulty, or operating in extremely cold temperatures. Instal, replace or allow
the gobo to warm up.
G1ER
GOBO WHEEL ERROR
GELF
GENERATE EVENT LOG FAILED
GOER
GOBO WHEEL ERROR
The sensors, wiring and motor need to be checked and the driver PCB may need to be replaced.
HOT
LAMP TOO HOT TO RESTRIKE
The fixture will attempt to restrike at 20 second intervals. After 90 seconds if the lamp still refuses to
strike, LERR is displayed
HT W
HEAD TEMPERATURE TOO HIGH
One or more of the PCB's in the head is above 85 degrees celsius. Power off the fixture, allow it to
cool, and restart.
HTCO
HEAD TEMP CUT OFF
One or more of the PCB's in the head is above 95 degrees celsius. Power off the fixture, allow it to
cool, and restart.
HTER
HEAD TEMP HIGH
The temperature on a PCB in the head is high. A fan might be defective or the ambient temperature
may be too high.
IRER
IRIS ERROR
LAER
LAMP ERROR
The lamp is defective or has exploded, is missing, or the lamp cannot restrike after 90 seconds.
LSER
LAMP SENSING CIRCUIT ERROR (s/w versions from ver. 1.3)
Lamp sensing circuit reports that lamp should be on but is not actually on.
LSRR
LAMP SENSING CIRCUIT ERROR (s/w versions prior to ver. 1.3)
Lamp sensing circuit reports that lamp should be on but is not actually on.
LTIM
LAMP LIFE WARNING
Lamp on counter has timed out and it is time to change the lamp. The counter must be reset once
this is done.
MAER
MAGENTA ERROR
MALE
MAINS LOW
The input voltage on the electronic ballast is too low to strike the lamp.
MALW
MAINS LOW
Mains voltage is below acceptable level. The lamp may not be able to strike.
PAER
PAN ERROR
PANA
PAN NOT ADJUSTED
Pan needs to be adjusted by a qualified service technician.
PCDE
PAN/TILT CALIBRATE DATA PCB (s/w versions prior to ver. 1.3)
Unable to read/write data to external EEPROM board (calibrate date) on yoke
Table 5: Error messages