Full-text message
CALIBRATE DATA ZOOM/FOCUS
Unable to read/write data to external eeprom board (Calibrate Data) on Zoom/Focus module. The
cables need to be checked or the module may need to be replaced.
COM ERROR CHARGER
I2C communication between main controller and charger failed. The cables need to be checked or
the module may need to be replaced.
COM ERROR CMY
CAN communication between main controller and CMY driver failed. The cables need to be
checked or the driver may need to be replaced.
COM ERROR COOLING
CAN communication between main controller and cooling driver failed. The cables need to be
checked or the driver may need to be replaced.
COM ERROR EFFECT
CAN communication between main controller and effects driver failed. The cables need to be
checked or the driver may need to be replaced.
CLEAN EVENT LOG FAILED
COM ERROR PAN/TILT
CAN communication between main controller and pan/tilt driver failed. The cables need to be
checked or the driver may need to be replaced.
COM ERROR POWER UNIT
I2C communication between main controller and ballast failed. The cables need to be checked or
the module may need to be replaced.
COM ERROR UI
User interface communication failure. The cables need to be checked or the module may need to be
replaced.
COM ERROR ZOOM/FOCUS
CAN communication between main controller and zoom/focus driver failed. The cables need to be
checked or the driver may need to be replaced.
FIXTURE IS COLD
PCBs are below -20° C (-4° F)
COOLING NO CONNECTION
(s/w versions prior to ver. 1.3)
EFFECT NO CONNECTION
(s/w versions prior to ver. 1.3)
CMY NO CONNECTION
(s/w versions prior to ver. 1.3)
PAN/TILT NO CONNECTION
(s/w versions prior to ver. 1.3)
ZOOM/FOCUS NO CONNECTION
(s/w versions prior to ver. 1.3)
CTC ERROR
The sensors, wiring and motor need to be checked and the driver PCB may need to be replaced.
CYAN ERROR
The sensors, wiring and motor need to be checked and the driver PCB may need to be replaced.
DIMMER ERROR
The sensors, wiring and motor need to be checked and the driver PCB may need to be replaced.
DIMMER NOT ADJUSTED
Dimmers need to be adjusted by a qualified service technician.
EFFECT CALIBRATE DATA PCB
(s/w versions prior to ver. 1.3)
Unable to read/write data to external EEPROM board (calibrate date) on effect module
WRITING EEPROM DEFAULT(S)
No valid EEPROM in a CAN module. Writing default into the EEPROM based on the CAN address.
Module is possibly incorrectly connected
EEPROM INVALID/NO CONN.
No connection or EEPROM data invalid
ERROR FAILSAFE MODE
Module error detected during self-check at startup. Service intervention required. Fixture control
possibly disabled, depending on nature of error.
LAMP R FAN ERROR
LAMP L FAN ERROR
BOTTOM FAN ERROR
Table 5: Error messages