SPECIFICATIONS
CO Response Times:
70 PPM: 60-240 minutes,
150 PPM: 10-50 minutes,
400 PPM: 4-15 minutes,
Sensor Type:
Electrochemical
Operating Temperature:
o
o
40
F (4.4
C) to 100
Audible Signal:
Buzzer Horn Sounds 85 dB at 10 feet
Visual Signal:
• Green LED Indicates Power On
• Alarm Red LED Indicates CO Alarm
• Service Red LED Indicates Service Required
Detection Frequency:
Samples for CO every 10 seconds
LCD Display: Model CA6050
• Digital Read-Out of Current and Highest CO Levels Detected
• Peak Level Time Record (the total time Peak CO is detected within 10% of the
peak level)
• Display Tolerance ±20% from 70 to 400 PPM @ 50% RH, 72° F±5° (22° C±3° )
Sensor Life Monitor
Activates sensor expiration signal after five years of operation
Factory Sealed Lithium Batteries
Two non-replaceable, non-removable lithium batteries for minimum 5 years of
operation under normal conditions
Electrical Rating:
6VDC, 0.1 mWatts
o
o
F (37.8
C)