Advertisement

Quick Links

MS6540A
Infrared Thermometer
User Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MS6540A and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Mastech MS6540A

  • Page 1 MS6540A Infrared Thermometer User Manual...
  • Page 2: Table Of Contents

    CONTENTS CONTENTS 1. Product Overview.......1 5.6 Save /Recall /Delete A Record....7 2. Safety Precautions......1 6. Distance To Object Size Ratio (D:S ).......9 3. Appearance........4 7. Emissivity..........10 4. LCD..........4 8. Maintenance........11 5. Operation Instructions......5 8.1 Battery Replacement:.......11 5.1 Manual Measurement......5 8.2 Lens Cleaning.........12 5.2 Degree Celsius/ Fahrenheit Toggling......5 8.3 Housing Cleaning........12...
  • Page 3: Product Overview

    1. Product Overview • The battery should be replaced immediately in case the battery indictor ( ) is shown on display. This hand-held infrared temperature sensors (hereinafter • In case the temperature sensor does not function well, referred to as “temperature sensor”) can be used for please stop using it.
  • Page 4: Appearance

    The temperature sensor conforms with the 3. Appearance followingstandards: ■ EN61326-1 EMC(Electromagnetic Compatibility) ■ EN61010-1 ■ EN60825-1 Safety specifications Symbol and Safety Label The symbols and safety labels used on the temperature sensor and in this manual are listed in Table 1 and Figure 1.
  • Page 5: Operation Instructions

    1. Emissivity display. Emissivity is adjustable when EMS 5.4 Emissivity Settings symbol is on display. 5.4.1 Emissivity is a measure of the radiation energy of 2. °C/°F symbol (degree Celsius / Fahrenheit) the corresponding material. Most organic material 3. The first temperature display and painted surfaces or oxidized surfaces have an 4.
  • Page 6: Save /Recall /Delete A Record

    5.5.2 After the value is set, gently touch “MEM” key on 5.6.3 Repeat the above steps to record again. When a the panel to turn on/off the alarming mode. When record position number of “99” is shown, pressing under “alarming on” mode, “ ”...
  • Page 7: Distance To Object Size Ratio (D:s )

    6. Distance To Object Size Ratio (D:S ) 7. Emissivity The temperature sensor has an angle of view and a Emissivity is a measure of the radiation energy of the range of view, as shown in the picture below. corresponding material. This temperature sensor allows you to adjust the emissivity of the sensor according to the type of the test surface.
  • Page 8: Maintenance

    Table 2. Surface Emissivity (continued) 8.2 Lens Cleaning Firstly, use clean compressed air to blow off any small Test Test Surface particles on the lens surface, and then use a damp 0.95 Steel Clay cotton swab to carefully clean the surface. You may use 0.95 Cold-Rolle 0.7-...
  • Page 9: Accessories

    ♦ Optical Resolution (D:S) (30:1) ♦ Co-axial laser aiming mode ♦ Temperature Resolution: 0.1 ºC or 0.1 ºF ♦ LCD with double temperature display and 4 bits ♦ MAX(highest), MIN(lowest), DIF(difference), and AVG(average)temperature display ♦ Emissivity adjustable (0.10 to 1.00), preset value: 0.95 ♦...

Table of Contents