Swegon CASA W3 Smart Instructions For Use Manual page 111

Heat recovery unit with counter-flow plate heat exchanger
Table of Contents

Advertisement

Available languages
  • EN

Available languages

location in the same room, the tempera-
ture sensor can be calibrated by changing
the room air fine tuning value.
• Display
ID. If two panels are installed in
the system, one is given the ID value 1 and
the second the ID value 2. Two panels with
the same ID number cannot be used in the
system.
Time.
Day.
• Screen
saver. If the "NOT Used" option
is selected for "Screen saver", the screen
goes dark, and Smart-functions and the
main menu symbols disappear. If the
"Function" is selected, a symbol corre-
sponds to the ventilation unit's operating
mode is shown.
• Screen saver
delay. The value for "Screen
saver delay" defines how quickly the
screen enters standby mode if you do not
press any buttons.
• Reset display
settings.
DIAGNOSTICS
From this menu you can check the data re-
lated to the function of the ventilation unit.
The various parts of the diagnostics are:
• Service
reminder.
Service reminder
Service reminder
Service interval
Next service
Reset counter
Whether the service reminder will be in
use or not is defined from this menu,
and determines the length of the service
interval. The menu also displays the time
remaining before the next service interval.
The counter can be reset if you are servic-
ing the unit before the service interval time
has been reached.
Swegon reserves the right to alter specifications.
Temperature.
Temperature
Fresh air
Supply air before re-heater
Supply air
Extract air
Exhaust air
Room air
Display
Water radiator
The temperature values shown in the
menu vary according to which sensors are
used in the unit.
• Smart
Smart functions
A+
AQ
RH
AH
AH setpoint
A+ control
6 m
RH control
6,0 m
AQ control
Smart control
The values shown in the menu vary accord-
ing to which Smart sensor is used in the unit.
The measurement values come from the
Smart sensors and the AH limit value is
the set limit for absolute humidity used by
auto humidity control, once boost starts.
The control information shows how much
different automatic Smart signals boost the
ventilation with respect to Home mode.
The
"Smart
total boost effect for all Smart functions.
Smart measurements: CO2, RH and VOC.
The absolute values in the measurement
result affect how well the control works.
www.swegonhomesolutions.com
functions.
11,8 g/m
12,6 g/m
control" value shows the
-12,2°C
11,8°C
16,9°C
22,3°C
-0,2°C
21,8°C
21,8°C
23,0°C
830 ppm
770 ppm
41 %
3
3
-3 %
0 %
4 %
1 %
EN