AC WIRING ORIGINATION

Lexan cover protects AC Wiring
Compartment Board

AC WIRING COMPARTMENT BOARD

����������
��������������
�����������������
�����������������
�������������
������������
��������
6
���������
AC Wiring Board
AC Terminal Block--secures AC
connections to the FX using set screws
• AC HOT OUT supplies power to the loads.
• AC NEUTRAL OUT acts as neutral leg for loads
supplied by the FX.
• CHASSIS GROUND connections are common
and act as grounds for both the incoming and
outgoing AC circuits.
• AC NEUTRAL IN acts as the neutral leg for AC
power supplied by either the grid or a generator
to the FX.
• AC HOT IN connects incoming AC from the grid
or a generator to the FX. This AC is used to run
loads and recharge batteries.
Note:
13.3 mm
(6 AWG) is
2
size the AC Wiring Compartment Board can
accommodate.
the largest wire