Outback GTFX2012E Installation Manual page 47

International series gtfx and gvfx grid-interactive inverter/charger
Table of Contents

Advertisement

48 Vdc System
DEFAULT
Charger
Float Voltage
54.4 Vdc
Absorb Voltage
57.6 Vdc
EQ Voltage
58.4 Vdc
ReFloat
50 Vdc
LBCO
42 Vdc
LBCI
50 Vdc
Absorb Time
1.0 hours
EQ Time
1.0 hours
Float Time
1.0 hours
Charger OFF/AUTO/ON
AUTO
Sell RE
52 Vdc
GenAlert & AUX
GenAlert Off Set Point
56 Vdc
GenAlert On Set Point
44 Vdc
GenAlert On Delay
4 min
GenAlert Off Delay
9 min
AUX Output Option
COOL FAN
Set AUX Control
AUTO
Vent Fan OFF Delay
5 min
Load Shed Off Set Point
44 Vdc
Vent Fan On Set Point
52 Vdc
Diversion On Set Point
58.4 Vdc
AC Output
Set Vac
230 Vac
AC Transfer
AC1/Grid Transfer Delay
6 AC cycles
Grid Lower Limit
208 Vac
Grid Upper Limit
252 Vac
AC2/Gen Transfer Delay
6 AC cycles
Gen Lower Limit
208 Vac
Gen Upper Limit
252 Vac
Stacking & Search
Stacking Phase
Master
Search Threshold
6 watts
Search Pulses
8
Search Pulse Spacing
60 AC cycles
Charge Rates & Input
Vented Model Charge Rate
9 Aac
Sealed Model Charge Rate
7 Aac
Grid Input Limit
30 Aac
Gen Input Limit
30 Aac
Input Select
Grid
MINIMUM
MAXIMUM
48 Vdc
600 Vdc
52 Vdc
64 Vdc
56 Vdc
68 Vdc
48 Vdc
52 Vdc
36 Vdc
48 Vdc
40 Vdc
56 Vdc
0.0 hours
24.0 hours
0.0 hours
24.0 hours
0.0 hours
24.0 hours
N/A
N/A
40 Vdc
60 Vdc
48 Vdc
72 Vdc
40 Vdc
56 Vdc
0 min
240 min
0 min
240 min
N/A
N/A
N/A
N/A
0 min
30 min
40 Vdc
56 Vdc
40 Vdc
64 Vdc
48 Vdc
64 Vdc
210 Vac
250 Vac
0 AC cycles
240 AC cycles
140 Vac
220 Vac
250 Vac
280 Vac
0 AC cycles
240 AC cycles
140 Vac
220 Vac
250 Vac
280 Vac
N/A
N/A
0 watts
50 watts
4
20
4 AC cycles
120 AC cycles
0 Aac
10 Aac
0 Aac
8 Aac
2.5 Aac
30 Aac
2.5 Aac
30 Aac
N/A
N/A
45

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gtfx2024eGtfx2348etGvfx2612eGvfx3024eGvfx3048e

Table of Contents