Electrical - aermotor FH50 Installation And Operation Manual

Fh series 1/2 and 3/4 h.p. 60 cycle shallow well jet pumps/ tank systems
Table of Contents

Advertisement

Available languages

Available languages

Electrical

Disconnect power before working on pump, motor, pressure switch, or wiring.
MOTOR SWITCH SETTINGS
Dual-voltage motors (motors that can operate at either
115 or 230 volts), are set at the factory to 230 volts. Do
not change motor voltage setting if line voltage is 230
volts, or if you have a single voltage motor.
NOTE: Never wire a 115 volt motor to a 230 volt line.
Remove Motor End Cover
If you have a dual-voltage motor, and will connect it to
115 volts, follow the procedure below.
End Cover Screws
Motor
End Cover
Figure 6: Removing Motor End Cover
You will need to remove the motor end cover to change
the voltage setting.
Your motor terminal board (located under the motor end
cover) should look like that shown below.
Ground
Screw
Voltage
Change Dial
Figure 7: Voltage set to 230 volts, Dial Type
To change to 115 volts:
Step 1. Make sure power is off.
Step 2. Turn the dial counter-clockwise until 115 shows
Step 3. The wires from the pressure switch should
Step 4. Reinstall the Motor end cover.
Pressure Switch Wiring
Motor wires connect here.
Connect the green (or bare copper) ground wire
to the green ground screw.
Figure 8: Pressure Switch Wiring
Step 5. Go to Wiring Connections below.
Connect ground wire before connecting power supply
wires. Use the wire size (including the ground wire) spec-
ified in the wiring chart. If possible, connect the pump to
a separate branch circuit with no other appliances on it.
supply line.
WIRING CONNECTIONS
fire or seriously damage the motor and voids the warranty.
The supply voltage must be within ±10% of the motor
Power Lead
Terminals
nameplate voltage.
NOTICE: Dual-voltage motors are factory wired for 230
volts. If necessary, reconnect the motor for 115 volts, as
shown. Do not alter the wiring in single voltage motors.
Install, ground, wire, and maintain your pump in compli-
ance with the National Electrical Code (NEC) or the
Canadian Electrical Code (CEC), as applicable, and with
all local codes and ordinances that apply. Consult your
local building inspector for code information.
in the dial window.
already be attached to to power lead terminals.
Power supply wires connect here.
230 Volt: Connect 2 hot wires (black and red)
here and cap the white (neutral) wire. It does
not matter which wire goes to which screw.
115 Volt: Connect one hot wire (black or red)
to one of these screws (it doesn't matter
which one). Connect the white (neutral) wire
to the other screw. Cap any remaining
black or red wires.
Clamp the power cable to prevent strain
on the terminal screws.
Hazardous voltage. Can shock, burn, or kill.
Explosion hazard. Do not ground to a gas
Fire hazard. Incorrect voltage can cause a
7