Orange Wire - Accessory (+) Output; Violet Wire - Start (+) Output; Pink/White Wire - Ign#2/Programmable (+) Output; 14 Pin Secondary Wire Harness - Excalibur RS-340-EDP+ Installation Manual

Deluxe keyless entry & remote start
Hide thumbs Also See for RS-340-EDP+:
Table of Contents

Advertisement

6 Pin Main Wire Harness (cont'd)

ORANGE WIRE - ACCESSORY (+) OUTPUT

This circuit is designed to drive accessory circuits like climate control, etc�� It
turns on when remote start is activated (slightly earlier than the primary ignition out-
put) and turns off only during engine cranking� It will turn back on for the remainder
of the remote start sequence.
CONNECTION: An accessory circuit is typically found at the ignition switch� The
proper circuit will show +12v when the ignition key is in the ON/RUN position but not
in the START position�

VIOLET WIRE - START (+) OUTPUT

REQUIRED� This output supplies positive voltage to the vehicle's starter circuit� If
using an anti-grind relay, connected this on the starter side of the relay�
CONNECTION: The starter circuit is typically found at the ignition switch� The proper
circuit will show +12v only when the ignition key is in the START position�
MANUAL TRANSMISSION: It is usually necessary to bypass the clutch switch dur-
ing remote start operations� Study the vehicle's schematics for the best approach�

PINK/WHITE WIRE - IGN#2/PROGRAMMABLE (+) OUTPUT

This output is programmable to act as an additional ignition, accessory, or start
output. It supplies positive voltage for powering any additional circuits required
for remote starting the vehicle� The default operation is as an ignition circuit� See
installer feature #2 for the settings that change this operation�
CONNECTION: The proper circuit will show +12v only when the ignition key is in the
position of the desired function� See the PINK, ORANGE, or VIOLET wire descrip-
tion for detail on your desired operation�

14 Pin Secondary Wire Harness

BLACK WIRE - SYSTEM GROUND (-) INPUT

REQUIRED� This input provides negative ground for all system operations�
CONNECTION: Using a properly sized ring terminal, connect this wire to the ve-
hicle's chassis� Using an existing bolt is preferred but make sure that the connection
point is clean and free of dirt, grease, or paint� Bright shiny metal at the connection
point is desired�

ORANGE WIRE - STATUS/ANTI-GRIND (-) OUTPUT

This provides a 500mA negative output slightly before and during the large PINK
ignition wire's operation�
CONNECTION: This is typically used to activate immobilizer bypass modules�
Connect it directly to the module's activation input� It can also be used with a starter
interrupt relay for starter anti-grind operation�

BROWN/RED WIRE - BRAKE PEDAL (+) INPUT

REQUIRED� This input is a critical safety circuit which disables the remote start
operation whenever the brake pedal is pressed�
CONNECTION: Connect this to the brake switch wire that shows +12 volts when the
brake pedal is pressed�