Available languages

Available languages

General Instructi ns (conti ued)
The appliance must be isolated from the gas supply
piping system by closing its individual manual
shuto valve during any pressure testi g of the gas
supply piping system at test pressures equal to or
less than 1/2 psi (3.5 kPa) (13.84 in W.C.).
You must follow the installa on instruc ons and
those in Care and Maintenance for adequate
combusti n air intake and exhaust.
INFORMATION
If the water heater is installed in a closed water
supply system, such as one having a back ow
preventer in the cold water supply line, means
shall be provided to control thermal expansion.
Contact the water supplier or local plumbing
inspector on how to control thermal expansion.
Should overhea ng occur or the gas supply fail to
shut off, turn o the manual gas control valve to
the appliance.
Keep the air intake locati n free of chemicals, such
as chlorine or bleach, that produce fumes. These
fumes can damage components and reduce the life
of the appliance.
NOTE
The MC-195T temperature controller is
contained within the Styrofoam packing of the
tankless water heater, be sure not to discard it.
This controller is necessary for opera on with this
tankless unit.
KBP Series Manual
Downloaded from http://GadgetsGo.com Rinnai Authorized Dealer
Prepare for installati n
Parts included
Tankless water heater with integrated pump
Color coded cold (blue) and hot (red) isolati n valves
Pressure relief valve
MC-195T temperature controller
Self Tapping Screws (Qty - 2)
Thermal By-Pass Valve

Tools needed

Pipe wrenches (2)
Adjustable pliers
Screwdrivers (2)
Wire cutt rs
Tools that might be needed
Hammer drill with
concrete bits
Saw
Threading machine with
heads and oiler

Materials needed

Soap or gas leak detector
soluti n
Approved ventin
Materials that may be needed
Heat tape
Pipe insulati n
Electrical wire and
conduit per local code
Concrete wall anchors
Opti nal pipe cover
Opti nal temperature
controller
5/8" ID PVC exible
tubing
2 conductor 22 AWG
Gloves
Safety glasses
Level
Core drill with diamond
head
Torch set
Copper tubing cutt r
Steel pipe cutt r
Thermal Expansion Tank
Te on tape
(recommended) or pipe
compound
wire for controller
Single gang electrical box
Wire nuts
Unions and drain valves
Additi nal Piping (for
dedicated return
applicati ns)
Pressure Regulator
Check Valve
Air Separator
5