Download Print this page

Rinnai SENSEI CU160e Manual

Tankless water heater
Hide thumbs Also See for SENSEI CU160e:

Advertisement

Available languages

Available languages

Quick Links

Advertisement

loading

Summary of Contents for Rinnai SENSEI CU160e

  • Page 1 ●...
  • Page 2 This conversion kit shall be installed by a qualified service agency in accordance WARNING with the manufacturer’s instructions and all applicable codes and requirements of the authority having jurisdiction. The information in these instructions must be followed to minimize the risk of fire or explosion or to prevent property damage, personal injury or death.
  • Page 3 For installations in Canada, the conversion shall be carried out in accordance with the requirements of the provincial authorities having jurisdiction and in accordance with the requirements of the CGA- B149.1, Natural Gas and Propane Installation Code. La Conversion Doit Être Effectuée Conformément Aux Exigences De L’autorité Provinciale Ayant Juridiction Et Aux, CSA B149.1, Code D’Installation Du Gaz Naturel Et Du Propane.
  • Page 4 IMPORTANT The French manual continues on page 10. (Le manuel en français continue à la page 10.) Model RU199 RU180 RU160 RU130 RUR199 RUR160 CU199 CU160 RSC199 RSC160 Minimum 15,000 15,000 15,000 15,000 Gas Consumption (Btu/h) Maximum 199,000 180,000 160,000 130,000 Minimum: 3.5 in.
  • Page 5 WARNING • If subsequent conversions are made, then a new conversion label must be placed on the water heater to accurately reflect the gas type. • Failure to correctly assemble the components according to these instructions may result in a gas leak or explosion.
  • Page 6 6. Remove the plastic orifice from the housing (Figure 2). 7. Install the new inner and outer gaskets onto the new orifice (Figure 2). 8. Install the new orifice into the housing. Check the gas type displayed on the orifice: red orifice is propane gas (LP);...
  • Page 7 IMPORTANT • Complete this section after completing section “4.1 Replace Orifice.” • Confirm that the inlet gas pressure is between the minimum and maximum pressures allowed for this appliance. CAUTION • Do not touch any other areas on the PC board other than the described buttons while power is supplied to the appliance.
  • Page 8 Read the section “For Your Safety Read Before Operating” in section “4.4 WARNING Operating Instructions” before starting the steps below. 1. Press the “On/Off” button on the controller to start the unit. The LED display will illuminate, the combustion fan will begin to run if water is flowing, and the spark will ignite the main burner. 2.
  • Page 9: For Your Safety Read Before Operating

    The following operating information is required by ANSI Z21.10.3 FOR YOUR SAFETY READ BEFORE OPERATING If you do not follow these instructions exactly, a fire or WARNING explosion may result causing property damage, personal injury or loss of life. A. This appliance does not have a pilot. •...
  • Page 10 IMPORTANT The French manual continues below. (Le manuel en français se poursuit ci-dessous.) Modèle RU199 RU180 RU160 RU130 RUR199 RUR160 CU199 CU160 RSC199 RSC160 Minimum 15,000 15,000 15,000 15,000 Consommation de gaz (Btu/h) Maximum 199,000 180,000 160,000 130,000 Minimum: 3.5 in. (0.87 kPa) W.C. Gaz Naturel Maximum: 10.5 in.
  • Page 11 AVERTISSEMENT • Toute conversion ultérieure requiert l’apposition d’une nouvelle étiquette de conversion sur le chauffe-eau afin de refléter correctement le type de gaz utilisé. • Un manque à assembler les composantes conformément à ces instructions peut entraîner une fuite de gaz ou une explosion. Lisez la section «Pour votre sécurité, lisez avant d'utiliser»...
  • Page 12 6. Retirez l’orifice en plastique du boîtier (Illustration 2). 7. Transférez les joints d’étanchéité interne et externe, de l’orifice original à l’orifice de rechange (Illustration 2). 8. Installez le nouvel orifice dans le boîtier. Vérifiez le type de gaz affiché sur l'orifice: l'orifice rouge est du gaz propane (LP);...
  • Page 13 IMPORTANT • Remplissez cette section après avoir terminé la section «4.1 Remplacement de l’orifice». • Confirmez que la pression de gaz à l’admission se situe entre le minimum et le maximum permis pour cet appareil. MISE EN GARDE • Ne touchez aucune partie de la plaquette de circuits autre que les boutons mentionnés alors que l’appareil est sous tension.
  • Page 14 Lisez la section «Pour votre sécurité, lisez avant d'utiliser» AVERTISSEMENT dans la section «4.4 Instructions d'Utilisation» avant de commencer les étapes ci-dessous. 1. Appuyer sur l’interrupteur allume l’écran à DEL; le ventilateur de combustion se met en marche si l’eau court et une étincelle allume le brûleur principal.
  • Page 15: Pour Votre Sécurité Lisez Avant De Mettre En Marche

    Les informations de fonctionnement suivantes sont requises par ANSI Z21.10.3. POUR VOTRE SÉCURITÉ LISEZ AVANT DE METTRE EN MARCHE AVERTISSEMENT Quiconque ne respecte pas à la lettre les instructions dans la pré- sente notice risque de déclencher un incendie ou une explosion entraînant des dommages, des blessures ou la mort.
  • Page 16 100000437(03) 03/2022...