Page 3
This procedure allows you to confirm your settings with the controller’s display. e. Gas Valve: - Why use a zero governor gas valve? Rinnai switched to this valve system in order to satisfy the PVC 2” air/exhaust venting requirement. The current proportional gas valve would not provide the air-fuel ratio with respect to the air quantity to accomplish this task.
Vent System - MUST use one of Rinnai’s listed and tested vent systems. Electrical System - MUST be properly sized for load at location. Refer to the National Electrical Code for details.
Page 10
Process orders Monday – Friday from 8 a.m. to 8 p.m. EST Ship from 8:00 a.m. to 6:30 p.m. EST Online ordering – Rinnai Parts Store 24/7 Warranty Department Available in office from 8 a.m. to 5 p.m. EST, Monday- Friday Technical Support Department –...
Page 11
4. Please refer to each model’s data sheet and/or service documentation for specific model information. 5. Rinnai pays reasonable labor, normally one hour for most all parts, exceptions; some condensing units pay two to three hours labor for burner or heat exchanger replacement.
Page 23
Overheat Safety Protection The Rinnai Safety “Line of Defense” Multiple layers of technology ensure safe operation Code 54 will post If the outlet on the controller, if Heat Exchanger bi-metal thermistor detects the exhaust opens at 230℉ and resets at 9°F over the...
Page 78
- Ensure Venturi isn't blocked. Venturi Blockage - Replace venturi and zero governor gas valve assembly. - Contact Rinnai for assistance in re-setting unit if error re-appears - Check components for an electrical short. Electrical grounding - Confirm all wiring harnesses are properly connected - If the P.C.
Page 79
Check fan motor for proper operation. – Replace gas valve. – Contact Rinnai for assistance in re-setting unit if error re-appears – Ensure inlet water temperature is not to high. – Check for blockage n the vent system’s intake or exhaust flue –...
* The heat exchanger warranty will be 15 years or 12,000 operation hours, whichever occurs first. ** From date of purchase, period of coverage is reduced to 8 years or 12,000 operation hours, whichever occurs first, if the Rinnai Water Heater temperature setting exceeds 160 °F (71 °C). •...
Page 84
Maintenance • Rinnai recommends that the inlet water filter be cleaned before the initial operation of a new unit and periodically thereafter. • Before removing the inlet filter, ensure that the water supply has been turned off, and all pressure...
Page 86
Heat exchanger flush procedure. The Rinnai SENSEI™ N - Series water heaters include a service indicated / reminder. When selected in the parameter settings an “SS” code will display on the controller indicating it is time to flush and service the water heater. Failure to service the appliance may cause damage to the heat exchanger.
Page 87
MUST be installed under the appliances. • Rinnai recommends the use of water treatment in hard water areas. • Water heaters utilizing a circulation system will require the installation of an expansion tank.
Page 90
• An adequate gas supply is critical for proper operation of all Rinnai water heaters. • The inlet gas pressure to the N-Series water heaters must be within the limits shown on the product’s rating plate, Natural Gas = 3.5” – 10.5” W.C. and Propane Gas = 8.0” – 13.5”...
Page 94
“High Flow Rate” will enable increased water flow through the water heater. Only licensed professionals who are trained for servicing Rinnai Tankless Water Heaters are permitted to adjust parameter settings. Adjust only the parameter settings discussed in this section;...
Page 95
“High Flow Rate” will enable increased water flow through the water heater. Only licensed professionals who are trained for servicing Rinnai Tankless Water Heaters are permitted to adjust parameter settings. Adjust only the parameter settings discussed in this section;...