5.8

Voltage Readings from the Controller

1
1. Water Valves
Varies between 13 – 22V DC
Note: Accurate voltages can only be
obtained by using a True RMS multimeter.
2. Pump Motor
230V AC
3. Supply Voltage
230-240V AC
4. Recirculation Valve
160 V DC
5.
Wash Motor
No accurate readings are possible
2
3
4
39
5
6. Lid lock
Pulses up to 30V when locking, when
locked, sits at approx 10V DC
7. Display Module
8. Thermistor
5 V DC
421827
6
7
8
5 V DC