Fisher & Paykel SMARTDRIVE Service Manual page 52

Hide thumbs Also See for SMARTDRIVE:
Table of Contents

Advertisement

421827
224
(11100000) Motor Control Module Fault
The motor control has encountered a peripheral error
Primary Fault:
Action:
225
(11100001) Motor Control Module Fault
The motor control has encountered a clock error
Primary Fault:
Action:
230.
(11100110) EEPROM Value out of Range
Wrong version detected
Primary Fault:
Action:
232.
(11101000) COMMS Timeout 5 Seconds
FabricSmart IW only problem, either the Display or Motor Control Module has not
responded in time.
Primary Fault:
Action:
Secondary Fault:
233.
(11101001) EEPROM Read Error
Problem in reading the EEPROM data, coming from the Motor Control Module
Primary Fault:
Action:
234. (11101010) Lid Lock Open Circuit
Check harness to Lid Lock, the connections at the Motor Control Module and lid lock ends.
Primary Fault:
Action:
Secondary Source: Lid lock has failed to be activated.
Action:
Tertiary Source:
Action:
235. (11101011) Lid Lock Short Circuit
Lid Lock fault, not activated when instructed to by the Motor Control Module.
Primary Fault:
Action:
236.
(11101100) Incompatible EEPROM Version.
Failed to start with fault being immediately displayed
Primary Fault:
Action:
237. (11101111) Temperature Sensor Error
The electronics have picked up a continuity problem, the same as fault code 10 or40.
Motor Control Module.
Change Motor Control Module.
Motor Control Module.
Change Motor Control Module.
Motor Control Module is the wrong version.
Change Motor Control Module.
Display Module.
Replace Display Module.
Motor Control Module.
Action: Replace Motor Control Module.
Motor Control Module fault.
Replace Motor Control Module.
Connectors on the harness at either end could be at fault.
Replace Lid lock assembly.
Replace Lid Lock Assembly.
Motor Control Module has not responded to the lid lock being
activated.
Check the lid has a tang and is fitted correctly to activate the lid lock.
If this is all in order, the Motor Controller must be faulty and needs
replacing.
Lid Lock mechanism has jammed or failed.
Check resistance across the connections, this should be 63 ohms +/-
C. If faulty, replace the Lid Lock assembly.
10% @ 20
Motor Control Module is wrong one.
Fit correct Motor Control Module.
52