System diagram
HR
NIBE air/water heat pump
VP
Principle of operation
SMO 10 is an advanced control module, which, together
with NIBE air/water heat pump and existing heating and
hot water equipment, creates a complete installation.
SMO 10 can be used for with several different connection
options. The base is the NIBE air/water heat pump, which,
in turn, can be docked on to electric boilers, oil-fired boil-
ers and accumulator tanks, for example, NIBE VPA.
P
SV1
CP*
PG
VXV1
UG
SÄV
AV
HR
LP1
TV
SMO 10
HR
FG1*
CP1
UKV*
RG1
SÄV
VVG
SF
RV
Abbreviations
AV
Shut-off valve
BV
Non-return valve
EXP
Expansion vessel with necessary safety equipment
FG1
Flow line sensor 1
FG2
Flow line sensor 2
HR
Auxiliary relay
LP1
Charge pump 1
LP2
Charge pump 2
PG
Boiler sensor
RG1
Return line sensor 1
RG2
Return line sensor 2
RV
Control valve
SF
Particle filter
SV1
Shunt valve 1
SV2
Shunt valve 2
SÄV
Safety valve
TV
Drain valve
UG
Outdoor sensor
VVC
Hot water circulation
VVG
Hot water sensor
VXV1 Three way valve 1
VXV2 Three way valve 2
CP1
Circulation pump 1
CP2
Circulation pump 2
NIBE SMO 10
SV2
FG2
CP2
RG2
RV
BV
BV
HR
( Included in NIBE air/water heat
pump)
User guide
General
HR
3