CHAP.08 - TROUBLESHOOTING
• Control unit main alarms
NUMBER
ALARM NAME
AL 1
BLACK OUT
AL 2
FUME PROBE
AL 3
FUME HOT
AL 4
VACUUM
FAILURE
POWER
AL 5
FAILURE
AL 6
EMPTY
PELLET
THERMAL SAFE-
AL 7
TY
LACK
AL 8
DEPRESS-
CAUSE AND/OR REASON FOR ALARM
• Lack of electricity
• During normal operation, there was an absence of
electricity for a longer time of the parameter BLACK-
OUT
• Fume probe fails or is not properly connected elec-
trically to the circuit board.
• Fume temperature above a threshold of 260 ° C
• Fan speed does not smoke for the value of set-point.
• Fume fan electrically connected incorrectly.
• Fume fan very dirty or even blocked by deposit or
ash.
• Fan failure.
• The smoke temperature Pr13, is not reached within
the time Pr1.
• Lack of pellets in the drum.
• Basket is very dirty and does not allow the normal
start
• Electrical resistance of power failure.
• Start after the heater has reached the reservoir pel-
let without the initial load.
• The auger gear motor is faulty.
• During THIS FIRE (flame stabilization) the flue gas
temperature is not maintained.
• The Cauldron is positioned incorrectly.
• The smoke Temperature, in the working phase,
decreases to the threshold of Pr 31.
• The flow rate of pellet and / or wind speed smoke in
1st power is not correct to maintain the flame.
• Presence of at least one of two thermostats Security
PELLET tank.
• Intervention of the thermostat tank PELLET 85 ° C,
with manual reset.
• Speech by the tank thermostat pellet, 70 ° C in con-
tact with automatic reset.
• Activation of the security MANOSTAT on the delive-
ry of the smoke exhaust fan, or the tank lid or pellet
stove door is open.
For other alarms not on the list, for persistant problems or for those different from the ones
described above, seek Technical Assistance.
• Check the electrical connection between the socket
on the back of the heater and the connecting cable to
the mains is carried out properly.
• Check that the fuse in the electrical socket is intact.
• Check that the terminals of the electrical wiring of the
heater are well implanted in the unit.
• Make sure it is properly connected, the red wire to +
terminal of the controller and the probe is a thermo-
couple type J.
• Contact the Technical Assistance Center.
• Contact the Technical Assistance Center.
• E 'set an incorrect value to the parameter MAXIMUM
THRESHOLD.
• Visually and manually check that the fan turns freely.
• Check the wiring of the fan and the terminal ENCO-
DER.
• Check the contents of pellets in the tank.
• Check that the pellet feed auger is operating correctly
(press the Menu component from the TEST OUT).
• Check the cleanliness of the basket.
• Check the correct position of the Cauldron.
• Check that the electrical resistance functions (press
the Menu component from the TEST OUT).
• Adjust dosing time and speed pellet extractor hoods
for food and keep the flame properly.
• The Pellet tank is empty, restore the contents.
• Contact Technical Support for flow control and speed
PELLET smoke ventilation.
• Check flow pellets.
• Check the correct position of the sensing element of
the thermostat. (See drawings of the user manual).
• Check the correct setting of the thermostat.
• Adjust the flow of pellet at maximum power, may be
out parameter.
• The flow rates of pellets and smoke extractor fan
speed according to the calorific value of pellets.
• Make sure to clean the chimney -•
Verify the location of the chimney, no special winding
(see user manual)..
• Check if the fan fumes
• Adjust the calibration work in the new limit of work
pressure, ensuring the pull at maximum power.
• Close the door of the tank and pellet stove.